1-800-663-4209 | Bienvenue sur notre nouveau site Web, vous avez rencontré un problème ou un bug? Veuillez le signaler ici
TX64

Choisissez une variante
Input Type
Ajouté à votre panier
Configuration terminée.
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Échec de l'enregistrement des configurations, cliquez sur le bouton Configurer Recommencer
Spécifications du produit
<< Voir toutes les modèles de produitsBrand |
![]() |
Accuracy | ± 0.05 % |
Accuracy Detail | Transmitter Accuracy:±0.05% of the millivolt or Ω equivalent reading, or the accuracy from the table below, whichever is greater; plus ±0.05% of the span, if using a thermocouple sensor, allow a cold junction measurement error of ±0.5°C (±0.9°F), accuracy includes repeatability, hysteresis, load and ambient temperature Thermocouple Type: J: ±0.2°C K: ±0.2°C T: ±0.2°C E: ±0.2°C R: ±0.6°C S: ±0.6°C B: ±0.8°C N: ±0.2°C RTD Accuracy: ±0.1°C Voltage Accuracy: ±0.008 mV |
Additional Features 1 | Programmable temperature transmitter |
CMRR | 120 dB |
Calibration Adjustment | 100 % sensor range |
Cold Junction Compensation | ±0.5°C |
Diagnostics | Every 3 seconds, self-checks for zero, span, cold junction, calibration references, malfunction and sensor failure |
EMC Immunity Note | RFI Effect: <0.5% rdg (SAMA PMC 33.1c test) 20 kHz to 1000 MHz, 10 V/meter |
Electrical Output | 2-wire, 4 to 20 mA |
Input Control Signal | -15 to 160 mV |
Input Type | Thermocouple, RTD, Voltage |
Isolation | 850 Vdc or peak ac |
Linearity Error | ±0.05°C |
Load Resistance | 250 Ω |
Long Term Stability | < 0.05% of reading plus ±5 µA per year |
Operating Temperature, Max | 75 °C |
Operating Temperature, Min | -40 °C |
Output Signal | Current |
RTD Type | 100 Ω Pt Sensor,120 Ω Ni Sensor |
Repeatability | One-half of accuracy |
Resolution | ±2.5 µA |
Response Time | 0.25 sec; Update Time: 0.15 sec, digital, 1 sec |
Response Time Note | Analog 0.25 second typical; digital 1 second, typical to 95% of final value, 5 seconds to stated accuracy (Response to Step Input) |
Reverse Voltage | 42 Vdc applied with either polarity |
Sensor Break Detection | Analog, user settable to 21 mA, 3.9 mA or “OFF”, digital |
Start Up Time | <5 sec |
Storage Temperature, Max | 85 °C |
Storage Temperature, Min | -50 °C |
Supply Power Note | Minimum supply voltage under load, Vs = 12 + R (load in kΩ) X 23 mA; for digital operation |
Supply Power Type | DC |
Supply Voltage | 12 to 42 Vdc |
Temperature Compensation | Automatic compensation to 20°C/hour change, Self-correcting over operating temperature range |
Temperature Measurement Range | J: -210 to 1200°C, K: -270 to 1372°C, T: -270 to 400°C, E: -270 to 1000°C, R: -50 to 1768°C, S: -50 to 1768°C, B: 43 to 1820°C, N: 0 to 1300°C, RTD: -200 to 850°C |
Thermocouple Type | J, K, T, E, N, R, B, S |
Weight | 340 g |
Voir toutes Spécs |
Afficher les notes et les avis