DPU91-BC

Choisissez une variante
Control Mode
Mounting Orientation
Ajouté à votre panier
Configuration terminée.
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Échec de l'enregistrement des configurations, cliquez sur le bouton Configurer Recommencer
Spécifications du produit
<< Voir toutes les modèles de produitsBrand |
![]() |
Accuracy | ± 0.5 % |
Accuracy Detail | ± 0.5% or reading maximum error @ 25°C (77ºF) |
Additional Features 1 | Field Mount, Sensors |
Altitude,Max | 4000 m |
Conductivity Measurement | 0.0000 to 99999 μS |
Control Characteristics | Dry-Contact Relays: 2 Open Collector: 1 Type: SPDT N/A Form C: N/A Maximum Current Rating: 5 A resistive 50 mA DC Maximum Voltage Rating: 30 Vdc or 250 Vac Hysteresis Adjustable: Absolute in engineering units (EUs) Latch Reset: In test screen only Delay: 9999.9 seconds (maximum) Test Mode: Set on/off Cycle Time: 99999 seconds (maximum) Maximum Pulse Rate: 400 pulses/minute Proportional Pulse: 400 pulses/minute Volumetric Pulse Width: 0.1 to 3200 s Pulse Width Modulation: 0.1 to 320 s |
Control Mode | Batch Control |
Display Measuring Units | kΩ, MΩ, ms, ppb, ppm, μS |
Display Note | LCD Contrast: 5 settings |
Display Type | Backlit LCD |
Display Type Note | Backlit, 7 and 14-segment LCD |
Electrical Connection | Screw Terminal |
Electrical Output | 4 to 20 mA |
Enclosure Material | PBT |
Enclosure Ratings | IP65, NEMA Type 4X |
Flow Indication Note | Flow Rate: -9999 to 99999 units per second, minute, hour or day Totalizer: 0.00 to 99999999 units (program lockout or resettable) |
Form factor | 1/4 DIN |
Frequency | 0.5 to 1500 Hz |
Input Note | Digital Serial: ACSII, TTL level, 9600 bps Frequency Input: Sensitivity: 80 mV @ 5 Hz, gradually increasing with frequency Span: 0.5 Hz to 1500 Hz @ TTL level input |
Input Type | Pulse, S3L |
Input Type Note | Digital or AC Frequency: pH/ORP input via the digital output from the PHTX-2750 pH/ORP sensor electronics Conductivity/Resistivity: Input directly from OMEGA conductivity/ resistivity electrodes via direct conductivity/resistivity module or via CDTX-2850 |
Keypad | 4 buttons, injection-molded silicone rubber seal |
LED Indicators | “Dial-style” digital bar graph, LEDs for open collector, relays and warning indicator |
Measurement Type | Flow, pH, ORP, conductivity, salinity, pressure, temperature, batch |
Mounting | Specified to Omega field mount junction boxes |
Mounting Orientation | Field Mount |
Number of Channels | 1 |
ORP Measurement Range | -1999 to 1999.9 mV |
Output Detail | 4 to 20 mA (10.8 to 35.2 Vdc, 30 mA maximum) |
Over-Voltage Protection | 48 V transient protection device current limiting for circuit protection and reverse-voltage protection |
PH Measurement Range | 0 to 15 pH |
Relative Humidity | 0 to 100% condensing for field mount; 0 to 95% non-condensing for panel mount |
Repeatability | ±0.2% of reading |
Resolution | 1 μS |
Sensor Voltage | 4.9 to 5.5 Vdc @ 25°C, regulated short circuit protected |
Storage Temperature, Max | 70 °C |
Storage Temperature, Min | -15 °C |
Supply Power Note | DPU91 without Relay Module: 200 mA @ 10.8 to 35.2 Vdc DPU91 with Relay Module: 300 mA @ 10.8 to 35.2 Vdc |
Supply Voltage | 10.8 to 35.2 Vdc |
Update Rate | 1 sec |
Weight | 0.63 kg |
Wire Gauge | 14 AWG |
Voir toutes Spécs |