FMA2600-FVL2600-Series

Mass Flow Controllers with 20+ Gas Selection Feature

  • 130+ Gas Calibrations, Including: He, O2 , Neon, N2O, N2, Air, Argon, CO, CO2, Methane, Ethane, Propane, Butane, Acetylene, Ethylene, H2
  • Pressure, Temperature, Volumetric Mass Flow Simultaneously Displayed
  • Easy Operator Push Button Interface
  • NIST Traceability Standard
FMA2600-FVL2600-Series
From C$ € 0,00
Mass Flow Controllers with 20+ Gas Selection Feature FMA2600-FVL2600-Series FMA2600-FVL2600-Series
loading all models
Product Overview
  • Accuracy ± 0.8 %
  • Accuracy Detail ± (0.8% of reading + 0.2%FS)
  • Additional Features 1 Power Supply Included
  • Calibration NIST Certificate
  • Data Interface RS232
  • Display Type LCD
  • Electrical Connection 8-pin mini DIN
  • Excess Flow Rate 2.4% FS
  • Height 3.9 in
  • Humidity Range 0 to 100% RH non-condensing
  • Input Control Signal 0 to 5 Vdc
  • Materials, Wetted Aluminum, Epoxy, FKM, Glass, Gold, Silicone, Stainless Steel
  • Media Compatibility Air, Gases, Nitrogen, Oxygen
  • Operating Pressure, Min 0 psi
  • Operating Pressure Note 145 psig To Use in Volumetric Mode: Near atmosphere, 15 psig recommended maximum. Volumetric flow meters and controllers not certified for accuracy at mass flow rates above the rated flow range of the meter. They are designed for near atmospheric pressure conditions only. The recommended maximum operating pressure is 15 psig
  • Operating Temperature, Max 50 °C
  • Operating Temperature, Min 0 °C
  • Measurement Pressure, Min 5 psi
  • Repeatability ± 0.2%
  • Response Time 100 ms
  • Span Shift 0.02% FS/°C/atm
  • Turndown Ratio 200:1
  • Volumetric Flow Rate, Min 0.0025 SCCM
  • Width 1.1 in
The FMA-2600A Series mass and volumetric flow controllers use the principle of differential pressure within a laminar flow field to determine and control mass flow rate. A laminar flow element (LFE) inside the meter forces the gas into laminar (streamlined) flow. Inside this region, the Poiseuille equation dictates that the volumetric flow rate be linearly related to the pressure drop. A differential pressure sensor is used to measure the pressure drop along a fixed distance of the LFE. This, along with the viscosity of the gas, is used to accurately determine the volumetric flow rate. Separate absolute temperature and pressure sensors are incorporated and correct the volumetric flow rate to a set of standard conditions. This standardized flow rate is commonly called the mass flow rate and is reported in units such as standard cubic feet per minute (SCFM) or standard liters per minute (SLM).
The controller uses a true proportional valve coupled to the flow body to control flow using the integral PID loop controller. Standard units include a 0 to 5 V output (4 to 20 mA optional) and RS232 communications. The gas-select feature and the setpoints can be adjusted from the front keypad or via RS232 communications. Volumetric flow, mass flow, absolute pressure, and temperature can all be viewed or recorded through the RS232 connection. It is also possible to multi-drop up to 26 units on the same serial connection to a distance of 46 m (150').

Accessories

cables

RPL SINGLE 6'8-PIN MINI DIN CB
$76.60 / each
1 In Stock
8-PIN M MINI-DIN SINGLE 25'
$144.90 / each
0 In Stock
8 PIN M MINI-DIN DBL END 25'
$171.86 / each
3 In Stock
8-PIN M MINI DIN DOUBLE 6'
$91.94 / each
1 In Stock
6'' MALE 8PIN DIN CBL TO DB-9
$88.22 / each
0 In Stock
8 PIN M MINI-DIN RIGHT ANGLE
$93.16 / each
0 In Stock

installation hardware

Polypropylene Body, TUBE ID 1/16 in TO MALE 10-32UNF
$10.01 / each
0 In Stock

meters/controllers

24VDC UNIV PS W/ALL INTER ADPT
$137.91 / each
2 In Stock
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 11ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
en-NL
fr
Save Configuration