1-800-663-4209 | Bienvenue sur notre nouveau site Web, vous avez rencontré un problème ou un bug? Veuillez le signaler ici
OS-AO50-21-TC
Adjustable Output w/ Thermocouple option, 2:1 FOV, Fixed IR Sensor with built-in display

Choisissez une variante
Electrical Output
Ajouté à votre panier
Configuration terminée.
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Échec de l'enregistrement des configurations, cliquez sur le bouton Configurer Recommencer
Spécifications du produit
<< Voir toutes les modèles de produitsBrand |
![]() |
Cable Length | 3 m |
Control Output | Relay Output with hysteresis 60V DC/42V AC RMS,0.4A |
Data Interface | USB |
Display | Yes |
Détail de la précision | ± 1% of the measured value or 3°C whichever value is greater (The sensor head must be at constant ambient temperature for a minimum of 15 minutes) |
Electrical Output | 0 to 20 mA, 4 to 20 mA, 0 to 10 Vdc, Thermocouple Type K, Thermocouple Type J |
Emissivity, Max | 1.2 |
Emissivity, Min | 0.1 |
Enclosure Ratings | IP65 |
Field of view | 2:1 |
Housing Height | 33 mm |
Housing Length | 112.5 mm |
Housing Material | Stainless Steel,Zinc |
Housing Width | 82.5 mm |
Intrisically Safe | No |
Isolation | Power supply, *Digital output and Analog output are galvanically isolated * Not applicable for USB 2.0 digital output |
Laser Output | false |
Laser Power | None |
Operating Temperature, Max | 120 °C |
Operating Temperature, Min | 0 °C |
Output Detail | 0 to 20mA, 4 to 20mA, 0 to 10V, Thermocouple Type “K” or “J”, Relay Output with hysteresis 60V DC/42V AC RMS,0.4A |
Output Signal | Current, Voltage, Thermocouple |
Photodetector Type | Thermopile |
Power Consumption | 2.5 W |
Process Temperature, Max | 800 °C |
Process Temperature, Min | 0 °C |
Relative Humidity, Max | 0.95 |
Relative Humidity, Min | 10% |
Relay Output | 60 Vdc |
Relay Output Note | Relay Output with hysteresis 60V DC/42V AC |
Repeatability | 0.003 |
Repeatability Note | 0.3% of reading + 1°C |
Response Time | 20 ms |
Response Time Note | 20 msec adjustable up to 10 sec |
Sighting Option | None |
Spectral Response, Max | 14 μm |
Spectral Response, Min | 8 μm |
Storage Temperature, Max | 70 °C |
Storage Temperature, Min | -20 °C |
Supply Power Note | 12V to 28V DC with reverse polarity protection |
Supply Voltage | 12 to 28 Vdc |
Temperature Coefficient | ± 0.06% |
Temperature Coefficient Note | ± 0.06 °C/°C (0.06 °F/°F) or ± 0.06 % (whichever is greater) |
Weight | 600 g |
Voir toutes Spécs |
PDF et manuels
Logiciels et pilotes
Étalonnage
Accessories
This is a air purge unit for the sensor head of the AO250 Models IR Sensors. Strongly recommended in areas where dust may build up on the IR sensor over time.
C$528.71
0 In Stock
This is a water cooling jacket accessory with a built in air purge for the AO250 Model IR Sensors. Recommended if ambient temperatures are near or higher then 70 °C (158 °F).
C$518.53
1 In Stock
This is a air purge unit for the sensor head of the AO50/50H Model IR Sensors. Strongly recommended in areas where dust may build up on the IR sensor over time.
C$292.95
0 In Stock
This is a converter for the OSAO-Series IR sensors to convert signals from RS-232 to RS-485 or RS-485 to RS-232.
C$366.79
0 In Stock
This is a communication PCB accessory to provide RS-232/RS-485 connectivity options to the interface of the OSAS-Series IR sensors.
C$164.44
2 In Stock
Afficher les notes et les avis
Rated 5 out of
5
by
Shweta Jaroli from
Great Performance
We are satisfied with performance of this pyrometer.
Date published: 2021-09-02
Rated 1 out of
5
by
SSmith from
Does Not Work
The display frequently freezes at a temperature and stops live updating. The power wires going into the device are exposed because the wrapping is too short. They will likely break from moving the device or rip out. The OmegaSoft data collection software will either record to an old file or say that it can't record because a file is active. The "Start" and "Stop" data collection functions do not work.
Date published: 2021-03-26