TX91A-92A-Srs-Tx

Miniature Low-Cost Temperature 2-wire Transmitters

Models In Stock
TX91A-92A-Srs-Tx
From C$ 172.00
Models In Stock
Miniature Low-Cost Temperature 2-wire Transmitters TX91A-92A-Srs-Tx TX91A-92A-Srs-Tx
loading all models
Product Overview
  • Accuracy ± 0.1 %
  • Accuracy Detail ±0.1% FS (includes effects of linearity, hysteresis and repeatability) referenced to the mV input
  • Calibration Trimpot/Switch
  • Diameter 44.5 mm
  • Dimensions Note 31.75 H x 44.5 mm Dia (1.25 x 1.75"); height includes terminal strip
  • Electrical Connection Screw Terminal
  • Electrical Output 4 to 20 mA
  • Height 31.75 mm
  • Hysteresis ±0.1%
  • Input Type Thermocouple
  • Linearity ±0.1%
  • Loop Resistance, Max (Vs-8V)/0.02A
  • Operating Temperature, Max 85 °C
  • Operating Temperature, Min -40 °C
  • Probe Length 0 mm
  • Repeatability ±0.1%
  • Sensor Type Transmitter
  • Setup Controls Trimpot/Switch
  • Sheath Material N/A
  • Storage Temperature, Max 121 °C
  • Storage Temperature, Min -46 °C
  • Supply Power Note 8 to 50 Vdc; 24 Vdc recommended
  • Supply Power Type DC
  • Supply Voltage 8 to 50 Vdc
  • Thermocouple Type K
  • Weight 34 g
  • Zero Setting Adjustable Range ±10%
TX91A and TX92A Series are discontinued. As an upgrade substitute, please check out the new TXUN temperature transmitter for details.

The non-isolated TX90A Series transmitters convert thermocouple or RTD signals into a 4 to 20 mA dc signal output that is directly referenced to the mV input of a thermocouple or resistance of a 100 Ohm platinum RD.

For thermocouple transmitters, the 4 to 20mA output is not linearized. T/C transmitters are available for type K, J, T, and E with color coding for each T/C type. The transmitters for RTD’s are available with the 4 to 20mA output directly proportional to the input resistance or with the 4 to 20mA output linearized to tempearature.
Note: RTD’s are slightly non-linear with the resistance diverging from actual temperature by approximately 1% at the mid point of full scale. (For linearized RTD transmitters, specify “RTD-L”. Non-linearized transmitters are the more popular choice).

The TX90A transmitters mount directly within OMEGA’s standard protection heads for connection to your sensor. OMEGA also provides complete thermocouple and RTD assemblies.


  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 2ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 27ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
en-CA
en_CA
Save Configuration