Skip to search Skip to main content Skip to navigation

1-800-663-4209 | Your feedback matters, take a quick survey Website Feedback

We noticed you are from . Visit your local site for regional offers and live support.

PX3005-DIFF

Rangeable, Differential Pressure Transmitters with Display

Models In Stock
PX3005-DIFF
From C$ 1 618.68
Models In Stock
Rangeable, Differential Pressure Transmitters with Display PX3005-DIFF PX3005-DIFF
loading all models
Product Overview
Rated 5 out of 5 by from Excellent product! Easy setup, easy calibration, excellent build quality. An outstanding, cost effective transmitter.
Date published: 2020-04-23
Rated 5 out of 5 by from GREAT purchased many times and always come back. Great product.
Date published: 2025-02-24
  • y_2025, m_4, d_30, h_7
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_2
  • loc_en_US, sid_PX3005-150DWBI, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT

In the data specs, is "TD" referring to "Total Differential"?

Asked by: abc123
TD means Turn Down, it is the ratio of the full-scale output over the current scaled output. Turndown = nominal range of the device/set span of the device
Answered by: Cyrus Grimes
Date published: 2023-12-18

Being outside the measurement range, can I have one side at 1 bar and the other at 100 bar? Or do I break the membrane ? (e.g. PX3005-150dwi sensors)

Asked by: PARQ
Hello, we do not recommend using this device outside the calibrated range. The diaphragm could see plastic deformation that could affect your zero and span balance. It would be best to go with a higher range.
Answered by: SAE J
Date published: 2024-07-08

Good afternoon, I need a pressure differential transmitter that measures 50 psi on one side and 14.13 psi on the other.

Asked by: tamayo1964
Tank you for your inquire. There a multiple choices and delivery times may be a factor. Please contact us directly.
Answered by: application engineer je
Date published: 2022-06-06

What is the approximate volume of one side of the cell? (We need to fill one side of a cell that is already installed with a relatively exotic fluid)

Asked by: LabWizard
Cavity volume of the process connection on the PX3005 Differential Transmitters in not readily available. Please contact our pressure product applications engineers directly at pressure@omgea.com. They will assist you in acquiring this information.
Answered by: Applications Engineer JK
Date published: 2023-09-25

wich cable shoud I use for computer connection? is it this one "Twist Lock Connectors for Pressure Transducers and Load Cells''

Asked by: Bramay
Bramay, no cable we have will help you connect to a computer. You will need a data acquisition system. Please email us at das@dwyeromega.com for help selecting a DAS device.
Answered by: SAE ENGINEER GUY
Date published: 2024-06-19

Of the ports that are marked (H) and (L), which of the two is the (IN) port and which one is the (OUT) port.?

Asked by: Emdott83
This is not a flow through sensor. The pressure applied to each port react on a internal diaphragm. The unit internally calculates the differential between the two applied pressures and output a signal represents this differential.
Answered by: Applicatrions Engineer JK
Date published: 2022-10-13

Just to confirm. The "WET/WET" means it is measuring pressure differential in fluid not in gasses. Correct?

Asked by: MarkM
Thank you for your inquire The units that state wet wet can be used in liquid or gas.
Answered by: application engineer je
Date published: 2020-12-18

I can range the -1000 to 1000 "H2O DP Transmitter to 0-278 "H2O. correct?

Asked by: belzebub
Yes they can. These unit are actually scalable so you can turn down the range of the unit do give you the full 4 to 20mA output signal over 0 to 278" wc.
Answered by: Applicatrions Engineer JK
Date published: 2021-02-09
  • y_2025, m_4, d_30, h_7CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_14
  • loc_en_US, sid_PX3005-150DWBI, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 9ms
  • QUESTIONS, PRODUCT
en-US
en_CA
Save Configuration