Skip to search Skip to main content Skip to navigation

Need assistance? Call us: 1-800-663-4209

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

ibtx-ibthx

iServer MicroServer™ Barometric Pressure, Temperature, and Humidity Transmitters

  • Virtual Chart Recorder
  • Web Server
  • Alarms by Email or Text Message
  • iBTX-SD: Record Years of Data on Popular SD Cards


The IBTHX Series recently received a hardware upgrade. If there's an issue with the probe during use, please refer to the link at the bottom of the page under 'Software and Drivers' to download the firmware update.

ibtx-ibthx
From C$ 836.02
iServer MicroServer™ Barometric Pressure, Temperature, and Humidity Transmitters ibtx-ibthx ibtx-ibthx
loading all models
Product Overview
  • AC Adaptor Operating Temperature 0 to 40 °C
  • Accuracy Detail Accuracy/Range at 25°C: Non-Condensing: 10 to 90%: 2.75% RH, 5 to 10% and 90 to 95%: ± 3% , 0 to 5% and 95 to 100%: ± 4%
  • Approvals CE, FCC-B
  • Battery Operating Temperature -18 to 55 °C
  • Configuration Internal Web UI
  • Data Interface Ethernet
  • Data Interface Note Ethernet (RJ45): 10BASE-T Protocols :TCP, UDP, ARP, ICMP, DHCP, DNS, HTTP, and Telnet
  • Hysteresis ± 1% RH
  • Input Type External
  • Measurement Type Barometric Pressure, Dew Point, Relative Humidity, Temperature
  • Non-Linearity ± 3%
  • Number of Measurements 3
  • Operating Temperature, Max 70 °C
  • Operating Temperature, Min 0 °C
  • Pressure Accuracy ± 3.5 mbar
  • Measurement Pressure, Max 110 kPa
  • Measurement Pressure, Min 1 kPa
  • Pressure Resolution 0.1 mbar
  • Relative Humidity Accuracy ± 2.75% for 10 to 90%; ± 3% for 5 to 10% and 90 to 95%; ± 4% for 0 to 5% and 95 to 100%
  • Repeatability ± 0.1%
  • Response Time Temperature: 5 to 30 sec, RH: 8 sec
  • Response Time Note Temperature: 5 to 30 seconds, tau 63%, RH: 8 seconds, tau 63%
  • RH Resolution 0.1%, 12 bit
  • Samples,Max 85k Samples, Interval 1 sec
  • Series ID ibtx-ibthx
  • Software OPC Server; macro for data logging in Excel program; compatible with Windows® operating systems
  • Storage Temperature, Max 85 °C
  • Storage Temperature, Min -40 °C
  • Supply Power Note Safety-Qualified AC Power Adaptor, Nominal Output: 9 Vdc @ 0.5 A , Input (iBT(H)X-W, iBTX-SD): 100 to 240 Vac, 50/60 Hz (included), Switching Power Supply (iBT(H)X-D): Sold separately (iDRN-PS-1000), Back-up Battery (iBTX-SD): 9V alkaline (included)
  • Temperature Accuracy ± 0.5 °C
  • Temperature Repeatability ± 0.1 °C
  • Temperature Resolution 0.1 °C

Supported Applications

The Omega iServer MicroServer™ Barometric Pressure, Temperature, and Humidity Transmitters (iBTX and iBTHX series) are Ethernet-connected transmitters designed for monitoring barometric pressure, temperature, relative humidity, and dew point. The system functions as a web server to serve active web pages displaying real-time readings, charts, and log data in standard formats compatible with spreadsheets or data acquisition programs.

Documented applications include:

  • Clean rooms
  • Computer rooms
  • HVAC systems
  • Pharmaceuticals
  • Laboratories

Operating Conditions & Performance

The series supports measurement ranges of 10 to 1100 mbar (1 to 110 kPa) for barometric pressure, 0 to 100% RH for relative humidity, and -40 to 85°C (-40 to 185°F) for temperature using the industrial probe. The wand probe supports a process range of 5 to 45°C (41 to 113°F).

Performance specifications vary by sensor type and range:

  • Barometric Pressure Accuracy: ±3.5 mbar at 25°C
  • Relative Humidity Accuracy: ±2.75% (10 to 90%), ±3% (5 to 10% and 90 to 95%), ±4% (0 to 5% and 95 to 100%)
  • Temperature Accuracy: ±0.5°C for wand probe (5 to 45°C), ±1°C for wand probe (0 to 5°C and 45 to 70°C); ±0.5°C for industrial probe (5 to 45°C), ±1.5°C for industrial probe (-40 to 5°C and 45 to 85°C)
  • Resolution: Barometric Pressure: 0.1 mbar; Relative Humidity: 0.1%, 12 bit; Temperature: 0.1°C, 14-bit
  • Hysteresis: ±1% RH
  • Repeatability: ±0.1% for humidity, ±0.1°C for temperature
  • Response Time (tau 63%): 8 seconds for humidity; 5 to 30 seconds for temperature

Ambient operating temperatures are 0 to 70°C (32 to 158°F) for iBT(H)X-W and iBT(H)X-D models, and 0 to 60°C (32 to 140°F) for the iBTX-SD model. Storage temperature is -40 to 85°C (-40 to 185°F).

Configuration Options

The series offers configurable mounting, probe types, and data logging options tailored to specific installation needs.

Housing & Mounting Options

  • DIN Rail Mounted Unit (-D): Polycarbonate case with DIN rail mount (iBTX/iBTHX-D). Dimensions: 115 mm (4.53 in) W x 90.2 mm (3.54 in) H x 25.1 mm (0.99 in) D.
  • Bench/Wall Mount Unit (-W): Valox® 364 PBT case with wall mount bracket (iBTX/iBTHX-W). Dimensions: 85.9 mm (3.38 in) W x 232.3 mm (9.15 in) H x 66.0 mm (2.60 in) D.
  • Bench/Wall Mount with LCD (-SD): Steel metal case with wall bracket mount, includes LCD Display, Flash Memory Card, and Backup Battery (iBTX-SD). Dimensions: 82.6 mm (3.25 in) W x 232.3 mm (9.15 in) H x 61.6 mm (2.42 in) D.

Probe & Sensor Configurations

  • iBTX: Barometric Pressure and Temperature only.
  • iBTHX: Barometric Pressure, Temperature, Humidity, and Dew Point.
  • Wand Probe (Standard): 159 mm (6.25 in) overall length, 19 mm (0.75 in) diameter; cable with DB9 connector or stripped wire leads depending on model.
  • Industrial Probe (-5 option): 137 mm (5 in) overall length, 16 mm (0.63 in) diameter stainless steel sheath; includes 3 m (10') cable with DB9 connector or stripped wire leads.

Data Output & Connectivity

  • Network: RJ45 Ethernet connector supporting standard TCP/IP packets and Web Server (HTTP, Telnet).
  • iBTX-SD Specifics: Includes 2 GB SD flash memory card for data logging in .txt file format; two 1.5 Amp relay outputs.

Power Supply Options

  • iBT(H)X-W and iBTX-SD: 9 to 12 Vdc (includes universal 100 to 240 Vac power adapter; includes 9V alkaline battery for backup on SD models).
  • iBT(H)X-D: 10 to 32 Vdc.

Key Product Differences

The primary distinction between the iBTX and iBTHX series is sensor capability: the iBTHX includes humidity and dew point sensing, while the iBTX measures only barometric pressure and temperature. The difference lies solely in the probe/sensor configuration.

  • Model Suffixes: Models ending in -D are DIN rail mounted; models ending in -W are bench/wall mount units with Valox® 364 PBT cases; models ending in -SD include an LCD display, flash memory card, and backup battery housed in a steel metal case.
  • Probe Types: Standard wand probes (152 mm/6" cable) are included unless the industrial probe option (-5) is specified. Industrial probes feature stripped wire leads or DB9 connectors depending on the base model configuration.

Accessories

accessories

CAL KIT FOR CT485B NACE
C$340.88 / each
0 In Stock

installation hardware

MOUNTING KIT,IND.PROBE
C$29.02 / each
98 In Stock

sensors

5" PROBE BAROMETRIC PRESSURE/TEMP/HUM,10
C$549.70 / each
1 In Stock
WAND PROBE,6"CABLE,BAR/TEMP/RH,DB9
C$529.62 / each
2 In Stock
5" PROBE BAROMETER/TEMP 10FT CABLE
C$357.45 / each
0 In Stock
BAROMETER/TEMP 10FT CABLE, DB9 CONN 5"PR
C$357.45 / each
0 In Stock
WAND PROBE/6"CABLE,BAR/TEMP,DB9
C$290.89 / each
0 In Stock
Rated 5 out of 5 by from Perfect Fit I purchased this unit to provide environmental data for our wind tunnel.
Date published: 2016-11-18
Rated 5 out of 5 by from Excellent Product Exactly what we were lookig for. The wait may have been a bit longer than expected, but it was worth it.
Date published: 2025-06-16
Rated 5 out of 5 by from Killer Application for Engineering/Scientific These sensors are very good. We have them in all our labs and offices. The output data is utilized with our own custom desktop application. Sensing humidity is also a big plus for us due to the organic sensors we make. The built-in server makes the sensor a powerful tool such that all in the company can use the data as a reference for the ambient environment. Now we cannot live without them...thanks much!
Date published: 2021-04-26
  • y_2026, m_8, d_7, h_10
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_3
  • loc_en_CA, sid_IBTHX-D, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 5ms
  • REVIEWS, PRODUCT

Hello team, We purchased 'IBTHX-D' model and we see 'Open' for all the reading Humidity, temperature, pressure in the webpage. Tried to restart couple of times. Infact may times in 2 weeks. This is recently bought just 2-3 weeks back.Please suggest.

Asked by: Sree
I am trying to capture Temp and Humidity to an output file but after execution the file is empty, and get no error. without the -o option I see expected readings in STDOUT. Here is CMD: C:\iServer_MicroServer\httpget.exe -o "C:\iServer_MicroServer\temp1.txt" -r -S "*SRB3\r" 192.168.63.75:2000
Answered by: TimKiely
Date published: 2025-06-02

Do have the latest firmware? The manual references 2.7.0 but here on your website is only 2.5

Asked by: JakeAU
. We will require more information to help on this question, please email the DAS team at DAS@dwyeromega.com
Answered by: PLVENG
Date published: 2025-04-11

Does this data logger uses a web interface that rely on Java? Is it compatible with recent web browsers?

Asked by: Prodigy
If you want to communicate with this device directly to its IP address on a web browser, it will require the latest version of Java in order to view the graphs. You can also use our Omega Enterprise Gateway software to monitor and record the data off of the device, which would not require Java.
Answered by: JA Engineer
Date published: 2019-11-21

I am trying to capture Temp and Humidity to an output file but after execution the file is empty. Here is CMD: C:\iServer_MicroServer\httpget.exe -o "C:\iServer_MicroServer\temp1.txt" -r -S "*SRB3\r" 192.168.63.75:2000

Asked by: TimKiely
Thank you for your inquiry. For product support please contact our Data Acquisition team at das@dwyeromega.com
Answered by: Application Engineer JB
Date published: 2025-06-02

What kind of measurement tolerance levels does the barometric pressure reading have in kPa for the iServer MircorServer?

Asked by: Best Project Engineer
Thank you for your question- Accuracy/Range at 25°C:±3.5 mbar/ From 10 to 1100 mbar (1 to 110 kPa)
Answered by: Application Engineer PV
Date published: 2022-07-19

I regularly have the problem that I can not connect to the sensor via the web interface after it has been supplied with voltage. I have to reset the sensor manually so that the sensor is accessible again and data can be queried.

Asked by: Paul_Dewe
Thank you for your question. We will require more information to help on this question, please email the DAS team at DAS@OMEGA.COM
Answered by: Application Engineer PV
Date published: 2022-04-27

I am trying to capture Temp and Humidity to an output file but after execution the file is empty. Here is CMD: C:\iServer_MicroServer\httpget.exe -o "C:\iServer_MicroServer\temp1.txt" -r -S "*SRB3\r" 192.168.63.75:2000

Asked by: TimKiely
Thank you for your question. We will require more information to help on this question, please email the DAS team at DAS@dwyeromega.com
Answered by: PVLENG
Date published: 2025-06-03

Looking for iconnect software download for my purchased iBTHX-D software manual. I cannot find the link on Omega's site.

Asked by: Russ D
Thank you for your question. We will require more information to help on this question, please email the DAS team at DAS@dwyeromega.com
Answered by: VPLENGR
Date published: 2024-08-27
  • y_2026, m_8, d_7, h_10CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_14
  • loc_en_CA, sid_IBTHX-D, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 6ms
  • QUESTIONS, PRODUCT
en-CA
en_CA
Save Configuration