Rated 1 out of
5
by
sadinky from
early failure and poor customer service
installed this on my city water feed and it failed within a week
tried to get a factory replacement without removing piping to retro fit the new meter
5 week wait
unacceptable!
Date published: 2024-03-05
How to convert the 4-20 mA to flow rates? Is there a linear correlation between these two parameters?
Omega suggests that at 4 mA equals to ZERO flow and at 20 mA equals to the maximum flow rate and is linear between these points? How are these points defined?
Date published: 2024-03-04
What is the cable connection type used on this meter? Is it possible to purchase a replacement connector and cable? If yes, what is the part number? I have one of these flow meters, but have misplaced the connector & cable.
Thanks for your question. The part # for the connector is LWGY. Please use link to order below.
https://www.omega.com/en-us/flow-instruments/flow-meters/turbine-flow-meters/p/LWGY
Date published: 2024-11-01
I'm interested in 804i & 810i, is there any calibration information if I purchase them?
Thank you for your inquiry! Unfortunately, we do not provide calibration documentation with the FTB-800 series flow meters
Date published: 2022-05-31
This flow meter can be used for 35% H2O2 liquid ? Model FTB-815-I Advise model no. for transmitter
Thank you for your inquiry! Unfortunately, the FTB-815-I would not be well suited for this application as the tungsten carbide rotor shaft will not be compatible with 35% H2O2. Please feel free to contact us using the email flow@omega.com with any further questions.
Date published: 2022-07-26
I have a FTB-815-I model and want to connect it to a DAQ. However, it seems that there are only two connectors 24V- and 24V+, while the manual indicates that the output should be 4 to 20mA. How do I connect this to a DAQ to read the current signal?
Thank you for your inquiry! The FTB-815-I is a two wire loop powered device. Typically the flow meter, a power supply, and a readout/recorder are all wired in a loop. The positive of the power supply goes to the positive of the flow meter, the negative of the flow meter goes to positive on the readout, and the negative of the power supply goes to the negative of the readout.
Date published: 2023-01-19
I got one FTB-815-I turbine meter 1", Could I conected in 1/2" size? Do you have a stainless steel 1/2" connector aditional accessory?
Thank you for your inquiry about the turbine flow meter. Unfortunately, there is no reducer available and in the event you must reduce the pipe diameter that much, please follow the straight run requirement upstream of at least 10x the diameter and 5x the diameter downstream.
Date published: 2021-03-15
How do I measure the 4-20mA output signal and transport it to my DAQ device?
Thank you for your inquiry about the turbine flow meter. Most DAQ systems can take a process analog input and if yours does not, then, best to contact our Data Acquisition Group at das@omega.com and they may have a module that will connect to your DAQ device.
Date published: 2021-10-25
I am purchasing the FTB-840-I flow meter. Can you provide the correct meter that will display the 4-20 output? Thanks
Thank you for your inquiry. The DPF64 is a display meter that will shw the flow rate only.
Date published: 2024-10-24