1-800-663-4209 | Welcome to our new website, found an issue or bug? Please report it here

DPI-Series
1/32, 1/16, 1/8 DIN, Programmable Temperature/Process Meters
Models In Stock
DPI-Series
From
C$
411.77
Models In Stock

Product Overview
Show Ratings & Reviews
Rated 4 out of
5
by
bobb from
Good Product
Pleased with the product. Easy to program , preforms well.
Shipping is a little slow, and even though I ordered the product from Omega located in Connecticut, the product shipped from California, and had I known this I would have selected a different shipping method.
Date published: 2016-03-29
Rated 5 out of
5
by
jsulzer from
Cost effective and flexible!
Replaced a unit that was damaged due to lightning strike. First one worked for years until millions of volts decided to destroy it. GREAT tech support when the manual and menu was less than obvious.
Date published: 2016-05-23
Is it possible to program the output to display a temperature reading directly correlated to the voltage input? (i.e. 2.175 VDC = 500°F or 4.51 VDC = 1000°F)
Yes, it can be done. If you start with the CNI32 or 16 or 8S, for strain, that unit has 10 point linearization and should be able to. However, we would like to better understand the application to confirm this and advise accurately. Please contact our Tech Support to best advise on the application and product recommendations. Thank you.
Date published: 2021-08-10
As a follow-up to the thread about the LCGB-500 load cell, if the DPiS32 is powering the load cell, which port does the shield cable connect to?
There isn't any provision on the DPiS32 to connect the shield from the load cell. You would need to connect it to an external earth ground.
Date published: 2025-01-21
Is the DPiS32 compatible with the LCGB-500 load cell?
Yes, The DPiS32 is compatible with the LCGB-500 load cell. It will both power and read the output signal directly from the load cell. Please note that the DC powered version of the display (DPiS32-DC) does not have the built-in excitation power to drive the load cell. External excitation power would need to be provided to the load cell if you use a DC powered version of this display.
Date published: 2025-01-18
Can you provide the ethernet cable wiring diagram?
Hi Jerry,
Thank you for the inquiry. Following linked manual provides wiring details of the ethernet cable.
https://assets.omega.com/manuals/M5023.pdf
Best regards
OMEGA
Date published: 2024-10-27
what does - opn mean on the display?
"OPN" on the display of the I Series panel meters means that the input signal is missing. Check wiring to the input to make certain connections are all there and complete and sensors attached are functioning properly. You can also check the INPUT type selected in the menu to make certain that the setting matches the actual input type being applied.
Date published: 2020-01-21
Is this compatible with LC103B-2K load cells?
The CNi/DPi Series controller/displays are not compatible with strain gage based sensors like the LC103B load cells. The CNiS/DPiS variants of this series are compatible with strain gage based sensors but they will only accept a unipolar input signal so you would not be able to use the load cell to measure in both tension and compression. Suggest you look at Platinum Series Controllers/Displays CN32PT,CN16PT,CN8PT,DP32PT,DP16PT and DP8PT.
Date published: 2024-03-01
RoHS 2015/863 - View Certificate
CE Approved
UKCA