1-800-663-4209 | Bienvenue sur notre nouveau site Web, vous avez rencontré un problème ou un bug? Veuillez le signaler ici

RAT-TJ
Thermocouple haute température avec gaine en céramique et fils de connexion
Modèles en stock
- High temperature Type R, Type S and Type B thermocouple probes
- Probe Temperature range up to 1650 °C (3000 °F)
- 1/4" diameter high purity ceramic protection tube
- Configurable for probe length, overbraid, wire gauge, connectors
RAT-TJ
Depuis
C$
864.34
Modèles en stock

L'aperçu du produit
- Cable Length 40 in
- Color Code Standard ANSI
- Insulation Note 1m (40") 24 AWG (0.020"); Solid Braided Fiberglass; Insulated Lead Wire
- Junction Type Ungrounded
- Number of Wires 2
- Probe Diameter 0.25 in
- Probe Type Rugged Transition Joint High-Temperature Thermocouple Probe
- Process Temperature, Max 1650 °C
- Process Temperature, Min 0 °C
- Sheath Material Ceramic
- Temperature Probe Style Extreme Temperature Probe
- Temperature Sensor Type Thermocouple
- Wire Type Solid
The Omega RAT-TJ is a high temp thermocouple built for peak performance in extreme environments, especially where both temperature and durability are required. Covered with a ceramic protection tube, this thermocouple probe excels at resisting oxidation and degradation at elevated temperatures.
Designed for use in oxidizing or reducing atmospheres and rated for service up to 1650 °C (3000 °F), the RAT-TJ offers reliable output for types R, S, or B thermocouples. The flexible lead wires with robust insulation make it easier to mount, route, and maintain in settings such as furnaces, lab test rigs, metal treatment processes, or thermal research setups.
With Omega’s legacy of accuracy, material quality, and customer support, this high temp thermocouple ensures dependable readings even under intense thermal stress. Whether for industrial process control, R&D, or production monitoring, the RAT-TJ combines rugged construction with precision.
View the Thermocouple Accuracy and Color Code charts
PDF et manuels
Afficher les notes et les avis
Rated 5 out of
5
by
Anonymous from
High quality B type thermocouple
This thermocouple has great quality and can be used at critical conditions.
Date published: 2023-06-02
Hello, what is the type of threads that are used on the mounting fitting (model no. SSLK-38-14 & SSLK-38-14)? E.g., NPT?
Thank you for your inquiry. SSLK-38-14 has a 1/4" NPT male.
Date published: 2024-11-14
Hello, It is possible this probe would function at -60degC?
Thank you for your inquiry. Unfortunately, these probes are not rated for measuring -60degC.
Date published: 2023-10-31