1-800-663-4209 | Bienvenue sur notre nouveau site Web, vous avez rencontré un problème ou un bug? Veuillez le signaler ici
PX409S15-16BI
16 to 32 inHg, Barometric, 4 to 20 mA, 1.5" Tri-Clamp, Cable
Choisissez une variante
Electrical Connection
Measurement Pressure Type
Measurement Pressure, Max
Measurement Pressure, Min
Précision
Spécifications du produit
<< Voir toutes les modèles de produits| Brand |
|
| ADC Resolution | None |
| Additional Features 1 | None |
| Bandwidth | DC to 1 kHz |
| Burst Pressure | 4x Full Scale to Maximum Rated Flange Pressure |
| Classe de précision | < 0.1% |
| Compensated Temperature, Max | 87.7 °C |
| Compensated Temperature, Min | -1.1 °C |
| Détail de la précision | ± 0.08% best straight line (linearity, hysteresis and repeatability combined) compound gage models calibrated in positive direction only |
| Electrical Connection | Cable |
| Electrical Output | 4 to 20 mA |
| Enclosure Ratings | IP65, IP67 |
| Fill Fluid | NEOBEE M5 food grade |
| Insulation Resistance | 100 MΩ @ 50 Vdc |
| Loop Resistance, Max | (Vs-9) x 50 Ω |
| Materials, Wetted | 316L Stainless Steel |
| Measurement Pressure Type | Barometric |
| Measurement Pressure, Max | 32 inHg |
| Measurement Pressure, Min | 16 inHg |
| Operating Temperature, Max | 115 °C |
| Operating Temperature, Min | -15 °C |
| Output Signal | Current |
| Pressure Cycles | 1 million |
| Process Connection Note | 1 1⁄2" and 2" Tri-GripTM (Tri-Clamp® compatible) Fitting: 600 bar using suitable clamp |
| Process Connection Size | 1 1/2 in |
| Process Connection Type | Tri-Clamp |
| Proof Pressure | 6x Full Scale up to 2000 psi |
| Précision | ± 0.08 % |
| Response Time | <1 ms |
| Shock | 50 g, 11 ms half sine (under test) |
| Shunt Calibration Value | 5-point NIST traceable calibration with zero and span values, calibrated in horizontal direction |
| Span Setting Adjustable Range | ± 0.5% FS |
| Stability | ± 0.1% |
| Supply Power Note | 9 to 30 Vdc [9 to 20 Vdc above 105°C (229°F)] |
| Supply Voltage | 9 to 30 Vdc |
| Thermal Effect on Span error, Max | 0.01%/°F |
| Thermal Effect on Zero error, Max | 0.01%/°F |
| Vibration | ± 20 g |
| Weight | 285 g |
| Zero/Balance Error | ± 0.5% |
| Zero/Balance Error Note | ± 0.5% FS typical ± 1% max (for ranges ≤ 5 psi ± 1% typ. ± 2% max) |
| Voir toutes Spécs | |
PDF et manuels
Logiciels et pilotes
Accessories
Afficher les notes et les avis