Sondes RTD industrielles (PT100) avec tête de protection en aluminium miniature
Nous avons remarqué que vous vous trouvez en . Veuillez consulter votre site local en cliquant sur le lien ci-dessous pour accéder aux offres et à l'assistance régionales.
Vibration
IEC 60068-2-6; 5 to 2000 Hz sweep rate, one active per minute; number of sweep cycles 10 and acceleration 5g (15 probes tested together) Duration: 1 day
Our PR-14 series RTD probe with miniature aluminum protection head and screw-on cap with chain includes PT100 „¦ platinum RTD element or PT1000 RTD element, 1/2" NPT mounting threads and sheath of 316 stainless steel. When properly sized, these can go directly into a thermowell. All probes include a screw terminal block for easy connection of insulated copper extension wire. Replacement probes (without head assembly) are available as well as a "spring-loaded" option which allows for the probe to bottom out in a thermowell for quicker and more accurate response. These are ideal for use in vessels, tanks and similar structures where temperature measurements are needed.
Inside dimensions for the aluminum head: Diameter: 1.5 inches; Height: 0.85 inches
Rated 5 out of
5 by
KatTexas from
Broad product lineOmega offers a broad line of products to fit any need.
Date published: 2024-09-24
Rated 5 out of
5 by
Steve Porter from
Order and Apply for chance at 100 dollar cardStumbled at the start but we got these to the customer and they are very happy.
Date published: 2024-07-15
Rated 4 out of
5 by
Wellhead Compression from
Good little RTDRTD's are great except for the fact that we have vibration in our equipment and the wires are so small they rub through or break.
Date published: 2024-07-08
Rated 5 out of
5 by
DinRail from
Excellent productExcellent option for submersible sensors in a damp environment.
Date published: 2023-04-16
Rated 5 out of
5 by
Katrina from
Will only purchase temperature devices from Omega!Omega has some of the best customer service in the industry. The products they offer have never failed. I don't know why anyone would even think of buying from another supplier.
Date published: 2023-01-06
Rated 3 out of
5 by
Head too small for TX401 from
Head too small for TX401Head too small for TX401. Had to remove head from another RTD to make this solution work
What is the difference between the old PR-14-2-100-3/16-6-E model and the newer PR-14E-3-100-3/16-6 device?
Asked by: MikeT
Thank you for your inquiry. The direct replacement for the PR-14-2-100-3/16-6-E is the PR-14E-3-100-3-16-6. There are no changes in shape, form and performance.
Answered by: Application Engineer MC
Date published: 2024-05-05
My company is looking for a stateside replacement but looking for a max of 350C is that possible?
Asked by: hayasa15
Thank you for your inquiry. Yes this device can handle temperatures up to 450°C.