Alerte: Les bureaux et les entrepôts d'expédition de DwyerOmega seront fermés pour les vacances du 25-26 Dec. et du 1 Jan, 2026
OM-CP-RTDTEMP101A
Precision RTD Temperature Data Logger
Choisissez une variante
Form factor
Ajouté à votre panier
Configuration terminée.
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Échec de l'enregistrement des configurations, cliquez sur le bouton Configurer Recommencer
Spécifications du produit
<< Voir toutes les modèles de produits| Brand |
|
| Battery Size and Type | Li-ion |
| Battery life | up to 10 yr |
| Calibration | Digital calibration through software |
| Commodity Code | 9025.80.5050 |
| Data Interface | USB |
| Data Interface Note | USB (interface cable required); 115,200 baud |
| DepthValue | 4.4 |
| ECCN | 3A992.a |
| Electrical Connection | Screw Terminal |
| Enclosure | Aluminium |
| Form factor | Benchtop |
| GrossWeightValue | 0.25 |
| Height | 16 mm |
| HeightUoM | IN |
| HeightValue | 2.5 |
| LED Indicators | Green LED Blinks: 10 second rate to indicate logging 15 second rate to indicate delay start mode ;Red LED Blinks: 10 second rate to indicate low battery and/or full memory 1 second rate to indicate an alarm condition |
| Length | 36 mm |
| Materials | ABS |
| Measurement Type | Temperature |
| Memory | 1340000 |
| Memory Modes | Yes |
| Memory Note | 1,340,000 readings; software configurable memory wrap 666,000 readings in multiple start/stop mode |
| NetWeightValue | 0.245 |
| Nominal Resistance | 18 - 400 Ω |
| Number of Measurements | 1 |
| OkForExport | true |
| Operating Temperature, Max | 80 °C |
| Operating Temperature, Min | -40 °C |
| Process Temperature, Max | 850 °C |
| Process Temperature, Min | -200 °C |
| RRS Code | 1 |
| Real Time Recording | The device may be used with PC to monitor and record data in real-time |
| Samples,Max | 670000 |
| Sampling Rate | 1 Hz (1 update/second) |
| Sampling Rate Note | 1 reading every second to 1 every 24 hours. |
| Series ID | OM-CP-RTDTEMP101A-Logger |
| Start Modes | Adjustable Delay Start, Immediate Start, Push-button |
| Stop Modes | Adjustable Delay Stop, Manual Through Software |
| Supply Power Type | Battery |
| Taxonomy Level 1 | MGI |
| Taxonomy Level 2 | DL |
| Taxonomy Level 3 | PO |
| Taxonomy Level 4 | PO |
| Temperature Resolution | 0.001 °C |
| Temperature Sensor Type | RTD |
| Time Accuracy | ± 1 minute/month |
| Waterbox Depth | 39 mm |
| Waterbox Height | 74 mm |
| Waterbox Width | 148 mm |
| Weight | 24 g |
| WeightUoM | LB |
| Width | 56 mm |
| WidthValue | 5.8 |
| Pays d'origine | United States |
| Voir toutes Spécs | |
Logiciels et pilotes
Accessories
Afficher les notes et les avis