<< See all Product Models| Brand |
|
| Approvals | CE Mark |
| Baud Rate | 9600 to 57600 |
| Control Characteristics | PID Control Settings:
Manual Output: 0 to 100% with 0.01% setting resolution Zone Control: 10 temperature zones with P, I, D, manual heater out, and heater range Setpoint Ramping: 0.1 K/min to 100 K/min Safety Limits: Curve temperature, power up heater off, short circuit protection |
| Control Output | Heater |
| Control Type | Manual Heater Output, Open Loop, PID Control |
| Conversion A/N | 24-bit |
| Data Interface | RS232 |
| Digital Connector Type | 9 pin Sub-D |
| Display Annunciators | Autotune, Control input, Remote |
| Display Measuring Units | °C, K, mV, V |
| Display Size | 5.5 mm Digits |
| Display Type | LCD |
| Display Type Note | Display: 2-line, 20-character, liquid crystal display with 5.5 mm (0.216”) character height Display Update Rate: 2 rdg/s Other Displays: Setpoint, heater range, and heater output; user selected |
| Détail de la précision | PTC RTD (0 to 500 Ω : Range) : ± 0.004 Ω, ± 0.01 % of rdg PTC RTD (0 to 5000 Ω : Range) : ± 0.004 Ω, ± 0.02 % of rdg NTC RTD (0 to 7500 Ω : Range) : ± 0.1 Ω, ± 0.04 % of rdg Thermocouple (± 25 mV) : ± 1 µV,± 0.05 % of rdg Thermocouple (± 50 mV) : ± 1 µV,± 0.05 % of rdg |
| Electrical Connection | Ceramic Isothermal Block |
| Filter | Averages 2 to 64 input readings |
| Form factor | Benchtop |
| Front Panel Display Readings | 1 to 4 |
| GrossWeightValue | 0.15 |
| Heater Output Display | Percentage of full power or current |
| Heater Output Resolution | 0.01 |
| Height | 89 mm |
| Input Type | Thermocouple, RTD, Thermistor |
| Input Type Note | Temperature, sensor units Input Configuration: Each input is factory configured for either diode/RTD or thermocouple |
| Interface Features | IEEE-488 Interface Features: SH1, AH1, T5, L4, SR1, RL1, PP0, DC1, DT0, C0, E1 |
| Isolation | Sensor inputs optically isolated from other circuits but not each other |
| Keypad | 20-key membrane, numeric and specific functions |
| Length | 368 mm |
| Loops | Control Loops : 2 |
| Measurement Type | Temperature |
| Number of Control Outputs | 2 |
| Number of Inputs | 2 |
| Operating Temperature, Max | 35 °C |
| Operating Temperature, Min | 15 °C |
| Output Detail | 2 Heater output |
| Output Signal | None |
| Power Consumption | 6 W |
| Précision | Selectable |
| RTD Type | 4-lead differential With 6-Pin DIN Connector |
| Resolution | Sensor dependent, refer to input specifications table |
| Sampling Rate | 10 Hz (10 updates/second) |
| Sampling Rate Note | To 10 rdg/s on each input |
| Sensor Input Configuration | Measurement Type: 4-lead differential Excitation: Constant current with current reversal for RTDs Supported Sensors: Diodes, silicon, GaAlAs; RTDs, 100 Ω Platinum, 1000 Ω Platinum, germanium, carbon-glass, CernoxTM, and RoxTM Standard Curves: CY7 and CY670, PT-100, PT-1000, RX-102A, RX-202A Input Connector: 6-pin DIN |
| Sensor Units Display Resolution | Sensor dependent up to 5 digits |
| Series ID | CYC325-Series |
| Setpoint Setting Resolution | Same as display resolution (actual resolution is sensor dependent) |
| Settable Parameters | Curve Entry, Keypad Lock-out |
| Software Support | LabVIEWTM driver; consult factory for availability |
| Supply Power Note | Standard 120 Vac, optional 240 Vac, 6%, -10%, 50 or 60 Hz, 85 VA |
| Supply Power Type | AC |
| Supply Voltage | 100 to 240 Vac |
| Temp Display Resolution | 0.001° from 0 to 99.999°, 0.01° from 100 to 999.99°, 0.1° above 1000° |
| Thermocouple Type | E, K, T, AuFe 0.07% vs Cr, AuFe 0.03% vs Cr |
| Tuning | Autotune, PID, PID zones |
| Update Rate, Max | 10 rdg/s on each input (except 5 rdg/s on input A when configured as thermocouple) |
| Weight | 4 kg |
| Width | 216 mm |
| Country of Origin | United States |