IBTHX-W
iServer MicroServer™ Barometric Pressure, Temperature, and Humidity Transmitters
Choisissez une variante
Form factor
RH Measurement Range
Supply Power Type
Probe Style
Ajouté à votre panier
Configuration terminée.
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Échec de l'enregistrement des configurations, cliquez sur le bouton Configurer Recommencer
Spécifications du produit
<< Voir toutes les modèles de produits| Brand |
|
| Approvals | CE, FCC-B |
| Battery Operating Temperature | -18 to 55 °C |
| Cable Length | 6 in |
| Cable Temperature, Max | 80 °C |
| Cable Temperature, Min | 0 °C |
| Configuration | Internal Web UI |
| Data Interface | Ethernet |
| Data Interface Note | Ethernet (RJ45): 10BASE-T Protocols :TCP, UDP, ARP, ICMP, DHCP, DNS, HTTP, and Telnet |
| Détail de la précision | Accuracy/Range at 25°C: Non-Condensing: 10 to 90%: 2.75% RH, 5 to 10% and 90 to 95%: ± 3% , 0 to 5% and 95 to 100%: ± 4% |
| Electrical Connection | Sub-D Male Miniature Connector |
| Form factor | Wall Bracket Mount |
| GrossWeightValue | 1.24 |
| Height | 1.08 in |
| Hysteresis | ± 1% RH |
| Input Type | External |
| Length | 3.67 in |
| Measurement Pressure, Max | 110 kPa |
| Measurement Pressure, Min | 1 kPa |
| Measurement Type | Barometric Pressure, Dew Point, Relative Humidity, Temperature |
| Non-Linearity | ± 3% |
| Number of Measurements | 3 |
| Operating Temperature, Max | 70 °C |
| Operating Temperature, Min | 0 °C |
| Pressure Accuracy | ± 3.5 mbar |
| Pressure Resolution | 0.1 mbar |
| Probe Diameter | 0.75 in |
| Probe Length | 6.25 in |
| Probe Style | Wand Probe |
| RH Measurement Range | 0 to 100% RH |
| RH Resolution | 0.1%, 12 bit |
| Relative Humidity Accuracy | ± 2.75% for 10 to 90%; ± 3% for 5 to 10% and 90 to 95%; ± 4% for 0 to 5% and 95 to 100% |
| Repeatability | ± 0.1% |
| Response Time | Temperature: 5 to 30 sec, RH: 8 sec |
| Response Time Note | Temperature: 5 to 30 seconds, tau 63%, RH: 8 seconds, tau 63% |
| Samples,Max | 85k Samples, Interval 1 sec |
| Sensor Type | Probe |
| Series ID | ibtx-ibthx |
| Software | OPC Server; macro for data logging in Excel program; compatible with Windows® operating systems |
| Storage Temperature, Max | 85 °C |
| Storage Temperature, Min | -40 °C |
| Supply Power Note | Safety-Qualified AC Power Adaptor, Nominal Output: 9 Vdc @ 0.5 A , Input (iBT(H)X-W, iBTX-SD): 100 to 240 Vac, 50/60 Hz (included), Switching Power Supply (iBT(H)X-D): Sold separately (iDRN-PS-1000), Back-up Battery (iBTX-SD): 9V alkaline (included) |
| Supply Power Type | DC |
| Supply Voltage | 9 to 12 Vdc |
| Temperature Accuracy | ± 0.5 °C |
| Temperature Repeatability | ± 0.1 °C |
| Temperature Resolution | 0.1 °C |
| Température de fonctionnement de l'adaptateur CA | 0 to 40 °C |
| Weight | 0.4 lb |
| Width | 2.6 in |
| Pays d'origine | Mexico |
| Voir toutes Spécs | |
PDF et manuels
Logiciels et pilotes
Accessories
Afficher les notes et les avis
Rated 5 out of
5
by
DocS from
Perfect Fit
I purchased this unit to provide environmental data for our wind tunnel.
Date published: 2016-11-18
Rated 5 out of
5
by
Gerry Sepulveda from
Excellent Product
Exactly what we were lookig for. The wait may have been a bit longer than expected, but it was worth it.
Date published: 2025-06-16
Rated 5 out of
5
by
FrankDLT from
Killer Application for Engineering/Scientific
These sensors are very good. We have them in all our labs and offices. The output data is utilized with our own custom desktop application. Sensing humidity is also a big plus for us due to the organic sensors we make.
The built-in server makes the sensor a powerful tool such that all in the company can use the data as a reference for the ambient environment.
Now we cannot live without them...thanks much!
Date published: 2021-04-26