Skip to search Skip to main content Skip to navigation

1-800-663-4209 | Bienvenue sur notre nouveau site Web, vous avez rencontré un problème ou un bug? Veuillez le signaler ici

Nous avons remarqué que vous vous trouvez en . Veuillez consulter votre site local en cliquant sur le lien ci-dessous pour accéder aux offres et à l'assistance régionales.

FP7001-Fittings

Installation de raccords pour les débitmètres à palette de la série FP7002

Modèles en stock
  • Dedicated fitting for FP7002 paddle-wheel flow meters ensures secure, accurate insertion
  • Adaptable to your piping system with multiple NPT/flange thread sizes and fitting options
  • Rated for up to ~150 psi (10.3 bar) and ~93 °C (≈200 °F) process conditions
  • Simplifies installation and maintenance of insertion flow meters with minimal downtime
FP7001-Fittings
Depuis C$ 207.59
Modèles en stock
Installation de raccords pour les débitmètres à palette de la série FP7002 FP7001-Fittings FP7001-Fittings
loading all models
L'aperçu du produit
  • Operating Pressure, Max 150 psi
  • Process Temperature, Max 93 °C

The Series FP7001-Fittings provide an essential installation accessory designed specifically for use with the FP7002 series insertion-type paddle wheel flow meters. These fittings allow precise mounting of the flow sensor into your process piping system while maintaining accurate measurement, leak integrity and alignment.

Manufactured to match the durability and service environment of the paddle-wheel meter, the FP7001 fittings accommodate a variety of pipe sizes and connection types, enabling flexible retrofits or new installations. With a pressure rating up to approximately 150 psi and temperature handling up to roughly 93 °C, they are suitable for many industrial liquid-flow applications.

By using the correct installation fitting, you ensure that the paddle sensor is mounted securely, aligned properly and supported by a stable housing. This helps reduce installation error, minimize measurement error and simplify service when the meter needs replacement or calibration. The Series FP7001-Fittings are a smart choice for ensuring reliable insertion-meter operation with maximum uptime.

  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 7ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

I'm using this fitting (FP7010) with a FP7001A Paddle wheel Flow & Temperature Sensor (FP7001A). Where do I find the K- Factor (Pulses/Gallon)? I did not see it specified in either user manual...

Asked by: Barty
Thank you for your inquiry. The K-factors can be found in the FP7001A datasheet. The K-Factor for the FP7010 fitting is 70.53 pulses per gallon.
Answered by: AS Engineer
Date published: 2020-11-10

Is this a "Tee" fitting with two FNPT ports or a Bushing that goes into a FNPT port.

Asked by: JBONJA
FP7010-GI is a T fitting with FNPT on both sides.
Answered by: AE HPO
Date published: 2023-01-06
  • y_2025, m_12, d_3, h_9CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_2
  • loc_en_CA, sid_FP7007, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 23ms
  • QUESTIONS, PRODUCT
fr-CA
fr
Enregistrer la configuration