Spécifications du produit
<< Voir toutes les modèles de produits| Brand |
|
| Approvals | CE |
| Approvals Note | EN-61326, Class B (battery operation) |
| Battery Size and Type | Alkaline AA |
| Data Interface | USB |
| Dimensions Note | 159 H x 70 W x 33 mm D excluding protrusions |
| Display Note | LCD with backlight Dot-matrix 128 x 64 dot (view area 41 x 29 mm), Operation key: 18-key including numeric key |
| Display Type | LCD |
| Détail de la précision | Thermocouple: 100°C or More: (±0.1% of measuring value +0.3°C) , 100°C or Less: (±0.1% of measuring value +0.6°C), DC Voltage: (±0.1% of measuring value +0.2% of range); ±0.4°C (at ambient temperature 15 to 35°C); ±0.7°C (at ambient temp. -10 to 15, 35 to 50°C) |
| Enclosure Ratings | NEMA Type 3 |
| Height | 6.2 in |
| Input Control Signal | 0 to 5 Vdc |
| Input Current | 0 to 20 mA |
| Input Resistance | DC voltage inputs over 1 MΩ |
| Input Type | Thermocouple, Voltage, Current |
| Length | 1.3 in |
| Loop Resistance, Max | 100 Ω (burnout over upper limit) |
| Materials | Nylon |
| Memory | 10000 Records |
| Memory Note | Log Mode: 10,000 data records/channel Tag Mode: 5500 data records/channel |
| Mounting | Handheld |
| Operating Temperature, Max | 50 °C |
| Operating Temperature, Min | -10 °C |
| Précision | ± 0.01 % |
| Relative Humidity | 10 to 80% RH no condensation |
| Sampling Rate | 1 sec to 24 hr |
| Sampling Rate Note | 1 second to 30 seconds (1 second steps) 1 minute to 24 hours (1 minute steps) Log Mode: Logging data per cycle (20 points) in log area Tag Mode: Logging data (20 points), then press the trigger in tag area |
| Series ID | OM-2041-Series |
| Supply Power Note | • 4 “AA” batteries or AC adaptor (100 to 240 Vac), • 500 hours or longer (at 25°C, 1-minute interval), • Backup log data, setting and clock by lithium battery with life of 5 years or longer (at 25°C). |
| Supply Power Type | Battery/AC |
| Supply Voltage | 100 to 240 Vac |
| Temperature Drift | ±0.01%/°C |
| Temperature Measurement Range | K: -200.0 to 1370.0°C,E: -200.0 to 700.0°C,J: -200 to 700.0°C,T: -200.0 to 400.0°C |
| Thermocouple Type | J, K, T, E |
| Type de prise d'alimentation AC | N/A |
| Weight | 10.5 oz |
| Width | 2.7 in |
| Withstand Voltage Note | 400 Vac |
| Voir toutes Spécs | |
PDF et manuels
Accessories
accessories
sensors
General Purpose Thermocouple Probes With Miniature Plug Connector
C$112.70 / each
0 In Stock
General Purpose Thermocouple Probes With Miniature Plug Connector
C$106.70 / each
7 In Stock
General Purpose Thermocouple Probes With Miniature Plug Connector
C$106.70 / each
91 In Stock
General Purpose Thermocouple Probes With Miniature Plug Connector
C$112.70 / each
12 In Stock
signal conditioners
Afficher les notes et les avis