Skip to search Skip to main content Skip to navigation

1-800-663-4209 | Bienvenue sur notre nouveau site Web, vous avez rencontré un problème ou un bug? Veuillez le signaler ici

Nous avons remarqué que vous veniez de . Visitez votre site local pour connaître les offres régionales et l'assistance en direct.

TXUN-FD-Temp-Transmitter

Field Mounted Hart Protocol Temperature Transmitter

Modèles en stock
  • RTD, TC, Ω, and Bipolar mV Input and Analog Output
  • High Definition Local Operator Interface (LOI) with 3 Optical Buttons
  • Selectable Red or White Backlight
  • Ex D Explosion Proof/Flame Proof in Aluminum or 316 Stainless Steel Version
TXUN-FD-Temp-Transmitter
Depuis C$ 1,499.19
Modèles en stock
Field Mounted Hart Protocol Temperature Transmitter TXUN-FD-Temp-Transmitter TXUN-FD-Temp-Transmitter
loading all models
L'aperçu du produit
  • Précision ± 0.05 %
  • Additional Features 1 Explosion Proof Aluminum/Stainless Steel Housing
  • Approvals EU RO Mutual Recognition Type; Approval: MRA0000009; ATEX 2014/34/EU: DEKRA 15 ATEX 0058 X; IECEx: IECEx DEK 15.0039 X; FM: FM16US0009X/FM16CA0010X; CSA: 70024231 EAC Ex TR-CU 012/2011: RU C-DK.GB08.V.01316; INMETRO: DEKRA 15.0014 X; NEPSI: GYJ15.1336X, GYJ15.1337X and GYJ15.1338X; SIL: Hardware assessed for use in SIL applications Authority Requirements: EMC: 2014/30/EU, EAC: TR-CU 020/2011
  • Calibration Adjustment ± 50 % Max
  • Calibration Temperature, Max 28 °C
  • Calibration Temperature, Min 20 °C
  • Data Interface HART 7, HART 5
  • Dimensions Note Aluminum: 109.3 H x 145 W x 126 D mm, Stainless: 107.4 H x 145 W x 124 D mm Dimensions: Ø 110 mm
  • Display LCD
  • Display Note 96 x 64 pixels Resolution, Selectable ON/OFF and Selectable white or red colour Backlight Number of Digits: 5
  • Electrical Output 4 to 20 mA
  • EMC Immunity Note Standard EMC Imunity: <±0.1% of span; Extended EMC Immunity: NAMUR, NE21, A Criterion, Burst: <±1% of span; Wire Size: 0.13 x 1.5 mm²
  • EMC Standard EN61010-1, EN61326-1
  • Enclosure Ratings IP54, IP66, IP68, NEMA Type 4X
  • Height 109 mm
  • Input Control Signal -800 to 800 mV
  • Input Control Signal Note Min. Measurement Range (Span): 2.5 mV
  • Input Resistance 10 MΩ
  • Isolation Test/Working: 1.5 kVac/50Vac
  • Length 104 mm
  • Load Resistance ≤ (Vsupply - 12) / 0.023 Ω
  • Long Term Stability ±0.1% of span/year
  • Operating Temperature, Max 85 °C
  • Operating Temperature, Min -40 °C
  • Operating Temperature Note -40 to 85°C (with Silicone O-ring),-20 to 85°C (with FKM Oring)
  • Output Detail Signal Range: 4 to 20 mA,Min. Signal Range: 6 mA,NAMUR NE43 Upscale/Downscale: 23 mA/3.5 mA
  • Output Load ≤ (Vsupply - 10) / 0.023 Ω
  • Output Signal Current
  • Potentiometer Input Range 0 to 7000 Ω
  • Programmable Functions HART Setup
  • Relative Humidity 0 to 100% RH Condensing
  • Resolution Input Signal Dynamics: 22 bit; Output Signal Dynamics: 16 bit
  • Response Time 1 to 60 sec; Update Time : 440 msec
  • RTD Input Note Cable Resistance, Per Wire: 50 Ω; Sensor Current: 0.2 mA
  • RTD Type 50/100/200/250/500/1000 Ω Pt Sensor, 50/100/120/1000 Ω Ni Sensor
  • Screw Terminal Torque 0.4 Nm
  • Sensor Break Detection Programmable 3.5 to 23 mA
  • Signal/Noise Ratio > 60 dB
  • Start Up Time 5 Sec
  • Storage Temperature, Max 85 °C
  • Storage Temperature, Min -40 °C
  • Supply Power Note Intrinsically Safe: 10 (12 - with backlight)...30 Vdc, Other: 10 (12 - with backlight)...35 Vdc
  • Supply Power Type DC
  • Supply Voltage 10 to 30 Vdc
  • Temperature Measurement Range J: -100 to 1200°C, K: -180 to 1370 °C, T: -200 to 400 °C, E: -100 to 1000 °C, R: -50 to 1760 °C, S: -50 to 1760 °C, N: -180 to 1300 °C, B: 0 to 1820 °C, W3: 0 to 2300 °C, W5: 0 to 2300 °C, L: -200 to 900 °C, LR: -200 to 800 °C, RTD: -200 to 850 °C
  • Thermocouple Type J, K, T, E, R, S, B, C, N, L, U, D, LR
  • Vibration ±4g
  • Vibration Note EC 60068-2-6; 2 to 25 Hz: ±1.6 mm; 25 to 100 Hz: ±4 g
  • Weight 1.3 kg
  • Weight Note Aluminum: 1.3, Stainless: 2.8
  • Width 23.5 mm
  • Wire Type Stranded

The Field Mounted Hart Protocol Temperature Transmitter (TXUN-FD) supports RTD, thermocouple, ohm, and bipolar mV inputs with a 4-20 mA analog output. Featuring a local LCD UI with front panel buttons, it offers ±0.05% accuracy and fast response times. Certified explosion-proof (Ex D) and compatible with Hart 5 and Hart 7 protocols, it meets multiple international approvals for safe industrial use.

Application
• Linearized temperature measurement with TC and RTD sensors e.g. Pt100 and Ni100.
• HART communication and 4...20 mA analog PV output for individual, difference or average temperature measurement of up to two RTD or TC input sensors.
• Conversion of linear resistance to a standard analog current signal, e.g from valves or Ohmic level sensors.
• Amplification of bipolar mV signals to standard 4...20 mA current signals.
• Up to 63 transmitters (HART 7) can be connected in a multidrop communication setup.
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 2ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

does Field Mounted Hart Protocol Temperature Transmitter comes without explosion proof housing?

Asked by: Anonymous
Thank you for the inquiry. TXUN-FD includes the rated housing. Please see manual for full details and ratings. Best regards OMEGA
Answered by: NorwalkAE_RS
Date published: 2023-04-17
  • y_2025, m_10, d_13, h_7CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_1
  • loc_en_CA, sid_TXUN-FD, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 4ms
  • QUESTIONS, PRODUCT
fr-CA
fr
Enregistrer la configuration