1-800-663-4209 | Bienvenue sur notre nouveau site Web, vous avez rencontré un problème ou un bug? Veuillez le signaler ici

FMA3000-Series
Contrôleurs et compteurs de débit massique pour tous les gaz propres
Modèles en stock
- For Flowrates Up To 10,000 mL/Min
- 0-5 Vdc Linear Output
- Cost Effective
FMA3000-Series
Depuis
C$
736.87
Modèles en stock

L'aperçu du produit
- Précision ± 1.5 %
- Additional Features 1 Requires 20-micron filter
- Electrical Output 0 to 5 V
- Enclosure Ratings IP10
- Height 3.5 in
- Leak Rate Under Vacuum less than 10^⁻4 cc He/s
- Length 1.87 in
- Media Compatibility Air, Gases, Nitrogen, Oxygen
- Operating Pressure, Min 0 psi
- Operating Temperature, Max 50 °C
- Operating Temperature, Min 10 °C
- Output Detail 0 to 5 Vdc (2500 Ω minimum)
- Output Signal Voltage
- Pressure Coefficient ± 0.02%/psi
- Pressure Drop, Max 1 inH₂O
- Process Connection Type Compression Fitting
- Repeatability ± 0.5%
- Response Time 2 sec
- Response Time Note 2 seconds (typical) to within ± 2% of actual flow rate from 25 to 100% of full scale
- Supply Current 100 mA
- Supply Voltage 12 to 15 Vdc
- Temperature Coefficient ± 0.2%/°C
- Turndown Ratio 10:1
- Volumetric Flow Rate, Min 2 SCCM
- Weight 0.44 lb
- Width 1.03 in
FMA3100 Series mass flow sensors represent a breakthrough in mass flow sensor technology. State-of-the-art electronics, a compact mechanical design, and mass production tooling concepts are combined into one high- performance, cost effective product. The gas flow sensor is suitable for many OEM applications. A 0 to 5 Vdc linear output is standard.
Using the basic FMA3100 thermal mass flow sensor, the FMA3200 mass flow controllers offer accurate, stable control of gas flows in a compact package. In power-off mode, the flow control valve is closed with a minimal leak rate. This cost-effective controller is ideal for many OEM applications, with a 0 to 5 Vdc linear output and a 0 to 5 Vdc control input.
The FMA3300s combine the features of the FMA3100 with an adjustable 3½ digit LCD digital display meter for viewing flow rate in engineering units (i.e., mL/min or L/min). These compact flow meters have proved effective in many laboratory applications.
Using the basic FMA3100 thermal mass flow sensor, the FMA3200 mass flow controllers offer accurate, stable control of gas flows in a compact package. In power-off mode, the flow control valve is closed with a minimal leak rate. This cost-effective controller is ideal for many OEM applications, with a 0 to 5 Vdc linear output and a 0 to 5 Vdc control input.
The FMA3300s combine the features of the FMA3100 with an adjustable 3½ digit LCD digital display meter for viewing flow rate in engineering units (i.e., mL/min or L/min). These compact flow meters have proved effective in many laboratory applications.
PDF et manuels
Accessories
cables
3 foot cable with mating connector and stripped ends. For use with power supplies which have terminal connections
C$103.53
3 In Stock
meters/controllers
115Vac Power Supply with input/output cable for FMA3100 and FMA3300 Series
C$287.05
6 In Stock
115Vac Power Supply with input/output cable for FMA3200 Series
C$250.00
0 In Stock
230Vac Power Supply with input/output cable for FMA3200 Series
C$294.91
0 In Stock
230Vac Power Supply with input/output cable for FMA3100 and FMA3300 Series
C$287.05
0 In Stock
Afficher les notes et les avis
Rated 5 out of
5
by
Tester Up from
Great
Just what I needed to keep a tester up and running. Fast shipping.
Date published: 2022-10-20
Do the FMA3200 series mass flow controllers (with both input and output) on sale anymore? I cannot find it on your website. I need a controller without LCD display. Thank you.
Thank you for your inquiry. The FMA3200 series controller have been discontinued. An alternative controller you could look at is the FMA5400 series. It does not have a display.
Date published: 2019-11-08
Is there a flow meter option that can operate under an external pressure greater than atmospheric conditions?
Thank you for your inquiry. The FMA1700/1800A series mass flow meter will operate with greater than atmospheric pressure.
Date published: 2024-07-25
Looking at FMA3104ST in the range of 20-200 sccm, will trace amounts of ammonia gas harm this?
Thank you for your inquiry! These units are not intended for use wit ammonia and we do not have tested data for the threshold at which damage will occur. If ammonia will be present we suggest using the FMA-1600A-LSS series intended for corrosive gases
Date published: 2022-04-15
Can the FMA3102 control the flowrate of a gas? Or does it just measure the flowrate?
Thank you for your inquiry. The FMA3102 is mass flow meter, meaning it only measures the flow rate of gas.
Date published: 2019-09-04