1-800-663-4209 | Bienvenue sur notre nouveau site Web, vous avez rencontré un problème ou un bug? Veuillez le signaler ici
OM-CP-PULSE101A
Pulse Input Data Logger

Choisissez une variante
Measurement Type
Ajouté à votre panier
Configuration terminée.
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Échec de l'enregistrement des configurations, cliquez sur le bouton Configurer Recommencer
Spécifications du produit
<< Voir toutes les modèles de produitsBrand |
![]() |
Accuracy | ± 1 min/month |
Accuracy Detail | ±1 minute/month at 20°C, stand alone data logging |
Battery Size and Type | 3.6V Li-ion |
Battery life | up to 10 yr |
Baud Rate | 115200 |
Data Interface | USB |
Display Measuring Units | °C, °F, ft/min, k/h, kts, m/s, mph |
Electrical Connection | Removable Screw Terminal |
Height | 2.5 in |
Impedance Input | >60 kΩ |
Internal Weak Pull-Up | <60 μA |
LED Indicators | Green LED Blinks: 10 second rate to indicate logging; 15 second rate to indicate delay start mode;Red LED Blinks: 10 second rate to indicate low battery and/or full memory; 1 second rate to indicate an alarm condition |
Length | 0.6 in |
Materials | ABS, Aluminum |
Measurement Type | Pulse |
Memory | 500,000 readings; software configurable memory wrap 250,000 readings in multiple start/stop mode |
Memory Modes | Yes |
Multi Start/Stop Mode Note | To start the device press and hold the pushbutton for 5 seconds, the device has started logging; to stop the device press and hold the pushbutton for 5 seconds while the device is logging, the device has stopped logging |
Number of Measurements | 1 |
Operating Temperature, Max | 80 °C |
Operating Temperature, Min | -40 °C |
Protection | An optional password may be programmed into the device to restrict access to configuration options. Data may be read out without the password. |
Pulse Rates | 10 kHz |
Pulse Width, Min | ≥ 10 µsec |
Real Time Recording | The device may be used with PC to monitor and record data in real-time |
Relative Humidity | 0 to 95% RH non-condensing |
Samples,Max | 1 sec |
Sampling Rate | 1 Hz (1 update/second) |
Software | XP SP3/Vista/7 and 8 (32 and 64-bit) |
Start Modes | Delayed Start, Immediate Start, Push-button |
Status Control | false |
Supply Power Type | Battery |
Voltage Input Range | 0 to 30 vdc |
Weight | 0.9 oz |
Width | 1.4 in |
Voir toutes Spécs |
PDF et manuels
Logiciels et pilotes
Afficher les notes et les avis
Rated 1 out of
5
by
RyanBrosInc from
Inaccurate
I bought this two months ago and have only used it once...and it was wildly inaccurate. Bench tested after reviewing the data and discovered it often times captured 3-7 pulses per known pulse input.
Date published: 2018-08-16