1-800-663-4209 | Bienvenue sur notre nouveau site Web, vous avez rencontré un problème ou un bug? Veuillez le signaler ici
FMG80A-Series
1/4 in to 3/4 in Pipe/Tube, Low Flow Electromagnetic Flow Meter
Modèles en stock
- No Moving Parts
- Requires No Straight Pipe
- Chemical and Corrosion Resistant
- Insensitive to Fluid Density and Fluid Viscosity Changes
FMG80A-Series
Depuis
C$
2,426.25
Modèles en stock

L'aperçu du produit
- Accuracy ± 1 %
- Cable Length 6 m
- Conductivity > 20 µS/cm
- Electrical Connection 8-pin mini DIN
- Enclosure Ratings IP66, NEMA Type 4X
- Materials PVDF
- Materials, Wetted PVDF
- Media Compatibility Acid Solutions, Conductive Liquids, Saltwater
- Number of Outputs 1
- Operating Pressure, Max 150 psi
- Operating Temperature, Max 54 °C
- Operating Temperature, Min -18 °C
- Output Detail Optocoupled current sinking or current sourcing pulse output; 30 Vdc, 5 mA max, 4 to 20 mA current loop; 7 Vdc plus load voltage drop min; 50 Vdc max
- Output Signal Current
- Process Connection Note Fittings with two NPT threaded adaptors (included)
- Process Connection Type NPT Male
- Process Temperature, Max 93 °C
- Process Temperature, Min 0 °C
- Supply Power Note 10 to 15 Vdc, 150 mA (linear power supply recommended)
- Supply Power Type DC
- Supply Voltage 10 to 15 Vdc
- Weight 0 lb
The FMG80A Series magmeter is designed for low-flow chemical injection or difficult-to-meter applications with pulsating metering pumps in ¼ to ¾" pipe/tube. The housing is made of sturdy splashproof HDPE plastic.
With no moving parts, the FMG80A Series can handle fluids containing particulate matter without clogging or jamming, keeping maintenance at a minimum. With no metallic parts (100% PVDF body and PVDF carbon fiber-filled electrodes), the meter is corrosion-resistant and compatible with a wide range of chemicals. Accuracy is maintained with conductive fluids (>20 micro Siemens) of varying viscosities and densities.
The FMG80A Series meter is compact enough to fit most pump/ injection systems. With zero straight pipe required after an elbow, it can be easily mounted in tight spaces. The mounting bracket adds stability. The FMG80A Series meter has opto-coupled current sinking or current sourcing pulse as well as a 4 to 20 mA output that can be connected to many OMEGA panel meters, controllers and data loggers; outputs and power are provided through a 6 m (19.7') cable with 8-pin female circular connector.
Specifications
Pipe Sizes: ¼, ?, ½, and ¾"
Fittings: Fittings with two NPT threaded adaptors (included)
Materials Body: PVDF
Electrodes: PVDF carbon fiber-filled
Ground: PVDF carbon fiber-filled
Housing: HDPE with glass fiber
Fittings: PVDF
Adaptors (NPT): PVDF or polypropylene
Temperature:
Ambient: -18 to 54°C (0 to 130°F)
Fluid: 0 to 93°C (32 to 200°F)
Pressure: 150 psi
Flow Range:
FMG81A, FMG82A: 3 GPM max (0.03 GPM cut off)
FMG83A, FMG84A: 20 GPM max (0.2 GPM cut off)
Accuracy:
FMG81A, FMG82A: ± 1%, ± 0.002 GPM of reading across rated range
FMG83A, FMG84A: ± 1%, ± 0.005 GPM of reading across rated range
Output Signal: Optocoupled current sinking or current sourcing pulse output; 30 Vdc, 5 mA max, 4 to 20 mA current loop; 7 Vdc plus load voltage drop min; 50 Vdc max
FMG81A, FMG82A: 1000 pulses/liter (3785 pulses/gallon)
FMG83A, FMG84A: 500 pulses/liter (1892 pulses/gallon)
Power: 10 to 15 Vdc, 150 mA (linear power supply recommended)
Fluid Conductivity: >20 microSiemens
Environmental: NEMA 4X (IP66)
Cable Length: 6 m (19.7'), cable with 8-pin female circular connector
Read More
With no moving parts, the FMG80A Series can handle fluids containing particulate matter without clogging or jamming, keeping maintenance at a minimum. With no metallic parts (100% PVDF body and PVDF carbon fiber-filled electrodes), the meter is corrosion-resistant and compatible with a wide range of chemicals. Accuracy is maintained with conductive fluids (>20 micro Siemens) of varying viscosities and densities.
The FMG80A Series meter is compact enough to fit most pump/ injection systems. With zero straight pipe required after an elbow, it can be easily mounted in tight spaces. The mounting bracket adds stability. The FMG80A Series meter has opto-coupled current sinking or current sourcing pulse as well as a 4 to 20 mA output that can be connected to many OMEGA panel meters, controllers and data loggers; outputs and power are provided through a 6 m (19.7') cable with 8-pin female circular connector.
Specifications
Pipe Sizes: ¼, ?, ½, and ¾"
Fittings: Fittings with two NPT threaded adaptors (included)
Materials Body: PVDF
Electrodes: PVDF carbon fiber-filled
Ground: PVDF carbon fiber-filled
Housing: HDPE with glass fiber
Fittings: PVDF
Adaptors (NPT): PVDF or polypropylene
Temperature:
Ambient: -18 to 54°C (0 to 130°F)
Fluid: 0 to 93°C (32 to 200°F)
Pressure: 150 psi
Flow Range:
FMG81A, FMG82A: 3 GPM max (0.03 GPM cut off)
FMG83A, FMG84A: 20 GPM max (0.2 GPM cut off)
Accuracy:
FMG81A, FMG82A: ± 1%, ± 0.002 GPM of reading across rated range
FMG83A, FMG84A: ± 1%, ± 0.005 GPM of reading across rated range
Output Signal: Optocoupled current sinking or current sourcing pulse output; 30 Vdc, 5 mA max, 4 to 20 mA current loop; 7 Vdc plus load voltage drop min; 50 Vdc max
FMG81A, FMG82A: 1000 pulses/liter (3785 pulses/gallon)
FMG83A, FMG84A: 500 pulses/liter (1892 pulses/gallon)
Power: 10 to 15 Vdc, 150 mA (linear power supply recommended)
Fluid Conductivity: >20 microSiemens
Environmental: NEMA 4X (IP66)
Cable Length: 6 m (19.7'), cable with 8-pin female circular connector