Product Specs

<< See all Product Models
Brand
Accuracy ± 0.75 %
Accuracy Detail ±0.75% of Reading (Liquid) (±0.5% of Reading: Typical Accuracy/ Non-Guaranteed) ±1% of Reading (Gas, Steam)
Commodity Code 9026.10.7000
Data Interface BRAIN Communication
Data Interface Note Communication Signal: BRAIN or HART communication signal (superimposed on a 4 to 20 mA DC signal) Note: HART is a registered trademark of the HART Communication Foundation. Conditions of Communication Line: Load Resistance:250 to 600 Ω(including cable resistance). Supply Voltage:16.4 to 42 V DC for digital communications BRAIN and HART protocols. (16.4 to 30 V DC for intrinsically safe type). BRAIN: Space from other Power Line: 15cm or more (Parallel wiring should be avoided.) Communication Distance: Up to 2 km,when polyethylene insulated PVC- sheathed cables (CEV cables) are used. Communication distance varies depending on type of cable used and wiring. Load Capacitance: 0.22 µF or less Load Inductance: 3.3 mH or less Input Impedance Communicating Device: 10 kΩ or more at 2.4 kHz.
DepthValue 17.7
Detector Type Integral
Display Type LCD
ECCN EAR99
Electrical Connection 1/2 in NPS female Conduit with Screw Terminal block
Electrical Connection Note In case of /FF1 or /CF1, CF11, /KF2, /KS2, /SF2, /SS2 the screw length is deeper than ANSI standard for 0.5 to 2 threads.
Electrical Output 4 to 20 mA, Two 125 mA SPST SSR
Enclosure Material N/A
Enclosure Ratings IP67 Type 4X (IEC 60529)
GrossWeightValue 13.31
HeightUoM IN
HeightValue 13.25
Materials, Wetted 316 Stainless Steel
Measurement Pressure Type Gauge
Media Compatibility Clean dry air / inert gas, Liquids, Steam
Mounting Plates Flange
NetWeightValue 13.305
OkForExport true
Operating Pressure, Max 412 psi
Operating Temperature, Max 250 °C
Operating Temperature, Min -29 °C
Output Detail Pulse output,alarm output and status output use the common terminal, therefore these functions are not used simultaneously. Output Signal (◇): Dual Output (Both Analog and Transistor contact output can be obtained simultaneously). In this case refer to the item “Remarks on installation” for power supply and pulse output wiring. Analog: 4 to 20 mA DC, 2-wire system. Transistor Contact Output*: Open collector, 3-wire system. Pulse,alarm,status output are selected by parameter setting. Contact rating: 10.5 to 30 V DC, 120 mA DC*1 Low level: 0 to 2 V DC. *1: 10.5 to 30 V DC. 80 mA DC for ATEX Intrinsically Safe Approval (/KS2) and IECEx Intrinsically Safe Approval (/SS2)
Process Connection Size 1/2 in
Process Connection Type ANSI Flange
Repeatability ±0.2%
Series ID FV500C-Series
Supply Power 10.5 to 42 Vdc
Volumetric Flow Rate, Max 26 GPM
Volumetric Flow Rate, Min 4.13 GPM
Weight 6 lb
WeightUoM LB
WidthValue 15.8
electrical-connection 1/2 in NPS female Conduit with Screw Terminal block
See All Specs Show Less
EOL FV-505C-F-D FV-505C-F-D

Accessories

Integral to Remote Electronics Display
C$2 752.20 / each
0 In Stock
This item is discontinued. Please contact Technical Sales Team for assistance.
Integral to Remote Electronics
C$1 990.16 / each
0 In Stock
This item is discontinued. Please contact Technical Sales Team for assistance.
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
en-CA
en_CA
Save Configuration