FHG1000-Series
Screw Gear Flow Meter for High Viscosity Liquids
- Pulsation-Free Measurement
- Lowest Pressure Loss for High Viscosity
- Short Response Time
- Up to 1,000,000 Centistoke Viscosity
FHG1000-Series
From
C$
13 014.08
Product Overview
- Accuracy ± 0.5 %
- Accuracy Detail ±0.5% of measured value with viscosity of > 21 cSt
- Display No Display
- Electrical Output Amplified Square Wave
- Enclosure Ratings IP65
- Media Compatibility High Viscosity Liquids
- Operating Temperature, Max 120 °C
- Operating Temperature, Min -30 °C
- Output Detail Iout = 300 mA maximum at 24 Vdc (channel 1, channel 2)
- Output Frequency 0 to 100 kHz
- Output Note Quadrature signals (A, B with 90° phase shift), Directional Output: Positive high (24V), negative low (0.8 to 1V), Error Output: Active high (24V), inactive low (0.8 to 1V), Signal Voltage Output: Vss = 9 to 27 Vdc (channel 1, channel 2, error/direction), Signal Output: Iout = 300 mA maximum at 24 Vdc (channel 1, channel 2)
- Power Consumption 65 mA at 24 Vdc
- Process Connection Type Flange
- Repeatability ±0.05%
- Supply Power Note u = 10 to 28 Vdc; reverse pole protection
- Supply Power Type DC
- Supply Voltage 10 to 28 Vdc
- Viscosity Range 1000000 cSt
FHG-1000 flow meters measure the flow rate based on the screw pump principle. A pair of rotors fitted precisely into the housing constitutes the measuring element. An integrated gear and non-contact signal pick-up system detects the rotations of the measuring element and converts them to digital pulses. Together with the housing walls, the rotor edges form closed measuring chambers in which the fluid is transported from the inlet to the outlet side. The fluid volume put through within one main rotor rotation is the rotation volume, which is divided by the sensing gear and digitized, processed and output in the sensor module.
Sensor System Explanation
The non-contact pick-up system consists of two GMR-bridges (sin/cos), which are located in a sensor unit in cartridge design. It detects the movement of the sensing gear and routes the sin/cos-signals to the preamplifier electronics. The preamplifier electronics digitize and amplify the sensor signals and multiply them by a high-resolution interpolator using adjustable settings. The square wave signals are bidirectional and can be utilized by any evaluating instrument as well as computers and PLC-controls. The resolution is selectable in steps from factor 1 to 128. In case of an 1-channel evaluation, a separate directional signal is available. An adjustable pulse filter can offset and suppress negative flows (e.g. generated by vibrations) while still in the device. The frequency of the output signals is proportional to the flow (volume flow) and depends on the respective flow meter size. The frequency range is from 0 to 100 kHz. The preamplifier is protected against reverse polarity and incorrect connection. It is suitable for fluid temperatures of -30 to 120°C (-22 to 248°F) and is mounted directly on the flow meter.
Sensor System Explanation
The non-contact pick-up system consists of two GMR-bridges (sin/cos), which are located in a sensor unit in cartridge design. It detects the movement of the sensing gear and routes the sin/cos-signals to the preamplifier electronics. The preamplifier electronics digitize and amplify the sensor signals and multiply them by a high-resolution interpolator using adjustable settings. The square wave signals are bidirectional and can be utilized by any evaluating instrument as well as computers and PLC-controls. The resolution is selectable in steps from factor 1 to 128. In case of an 1-channel evaluation, a separate directional signal is available. An adjustable pulse filter can offset and suppress negative flows (e.g. generated by vibrations) while still in the device. The frequency of the output signals is proportional to the flow (volume flow) and depends on the respective flow meter size. The frequency range is from 0 to 100 kHz. The preamplifier is protected against reverse polarity and incorrect connection. It is suitable for fluid temperatures of -30 to 120°C (-22 to 248°F) and is mounted directly on the flow meter.
PDFs & Manuals
Accessories
cables
Recommended connection cable 5 m (16.4 ft) long, M12 5-pin shielded, meter plug to stripped leads