Product Overview
  • Accuracy ± 0.25 %FS + 1 digits
  • Alarm Note 2 alarms operate the same relay; 3.0 A resistive 250 Vac; form A contact (SPST); field programmable for absolute (non-tracking) or deviation (tracking); can be set anywhere within the scaling of the controller; selectable inhibit and power interrupt; automatic/manual reset
  • Common Mode Rejection 140 dB minimum at 60 Hz
  • Control Characteristics Control Action: Reverse (heat) or direct (cool) action; selectable for single or dual setpoint models; Control Modes: Time-proportioning and proportional control modes; selectable preset tune, autotune or manual PID, P, PI or PD with reset anti-windup; Proportional Band : 6 to 5000°F or equivalent °C units; 6 to 9990 for voltage/current inputs; Integral Time : 0.1 to 99.9 minutes, or off ; Derivative Time: 0.01 to 99.99 minutes, or off ; Cycle Time: 2 to 80 s ; Approach Rate: Off to 99.99 min ; On-Off Control: Adjustable on-off differential 2° to full scale in 1° steps, 2 counts to full scale in 1-count steps (voltage/current inputs) ; Ramp and Soak: One ramp time and soak time each adjustable from 0 to 100 hours; end procedure can be set for HOLD or OFF
  • Cutout Dimensions 45 x 45 mm
  • Display Type 4 Digit LED
  • Enclosure Ratings NEMA Type 12, NEMA Type 2, NEMA Type 3R
  • Height 48 in
  • Impedance Input 3 MΩ min, thermocouple; 200 µA, RTD current; 249 Ω, current; 5 kΩ, voltage
  • Input Type Thermocouple, RTD, Voltage, Current
  • Isolation Relay and SSR outputs are isolated; current, voltage and logic outputs must not share
  • Length 125 in
  • Memory Non-volatile; no batteries required
  • Normal Mode Rejection 65 dB typical, 60 dB at 60 Hz
  • Operating Humidity 0 to 90% RH, non-condensing
  • Operating Temperature, Max 55 °C
  • Operating Temperature, Min -10 °C
  • Power Consumption 5 VA
  • Protection Loop Break Protection: Error message is initiated on shorted sensor or open heater circuit; break time adjustable from off to 99 minutes; Loop Break Alarm: On alarm relay equipped units, unit can be programmed to alarm on loop break
  • Sensor Break Protection De-energizes control outputs to protect system
  • Set Point Adjustment Selectable
  • Stability Line Voltage Stability: ±0.05% over supply voltage range; Temperature Stability: 4 µV/°C (2.3 µV/°F) typical, 8 µV/°C (4.5 µV/°F) maximum
  • Storage Temperature, Max 80 °C
  • Storage Temperature, Min -40 °C
  • Supply Power Type AC/DC
  • Supply Voltage 100 to 240 Vac, 132 to 240 Vdc
  • Weight 227 g
  • Width 48 in
  • Description
The Newest PLATINUM Series Controller CNPT is Available Now!

The CN76000 1/16 DIN PID controllers provide economical control for a wide variety of processes, includingheating, cooling, and heat/cool. When used with theproper transmitters, these devices can also controlpressure, flow, humidity, motion, or pH. The frontpanel is NEMA 2, 3R, and 12 rated for waterproofprotection and is corrosion resistant.
The sophisticated design of the CN76000 incorporatesthe latest microprocessor and surface mounttechnology, compressing an unprecedented number ofstandard features into a compact 1/16 DIN package. Theuser can program control functions from the frontpanel input types are DIP switch selectable. Multipletuning modes allow the user to select from 3 standardtuning presets, manual tuning, or autotuning.
Standard features include self-diagnosis with faultindication. Non-volatile memory retains all processparameters when power is off, without battery backup.Settings for the optional alarm are configurable. Thealarm action may be defeated on startup, or until theprocess value exceeds the alarm setpoint. The powerinterrupt feature will reset on power-up if the alarmcondition no longer exists.
Other standard features include min/max storage anddisplay, auto/manual control, percent output indication,ramp and soak operation, 4 user-selectable securitylevels with password protection, and jumper-selected5 Vdc pulse output to drive external solid state relays.Optional features include RS485 communications,process recorder output.
Note: CE not available with -485 commmunications option

Accessories

Control and Monitoring Accessories
C$55.74 / each
0 In Stock
Mounting Brackets
C$34.08 / each
0 In Stock
Control and Monitoring Accessories
C$253.06 / each
0 In Stock
Control and Monitoring Accessories
C$31.00 / each
0 In Stock
Control and Monitoring Accessories
C$34.08 / each
0 In Stock
Rated 4 out of 5 by from Autotune Controller Great Product!!!!!!!!!!!!!!!! Consistent Product that seems to always be in stock when needed.
Date published: 2025-10-22
Rated 5 out of 5 by from Good Customer Service Good Customer Service and fast product delivery that was on time.
Date published: 2024-05-02
Rated 5 out of 5 by from Great Product Omega controllers are cost effective, reliable, and simple to use. Our production plant trusts Omega controllers with some of our most critical safety systems.
Date published: 2022-08-12
Rated 4 out of 5 by from Great Service Prompt, Professional, and courteous service. Thanks
Date published: 2022-03-14
  • y_2025, m_12, d_3, h_9
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_4
  • loc_en_CA, sid_CN76020-PV, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT

Can I change the set point via RS485?

Asked by: bg03
Thank you for your inquiry. Yes, the set point can be changed via RS485.
Answered by: Application Engineer JB
Date published: 2020-02-12
  • y_2025, m_12, d_4, h_7CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_1
  • loc_en_CA, sid_CN76020-PV, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 3ms
  • QUESTIONS, PRODUCT
en-CA
en_CA
Save Configuration