Product Overview
  • Accuracy Transmitter: ± 0.2 °C or ± 0.2 % of Span, Sensor: Class A in accordance to IEC751
  • Accuracy Detail Transmitter: ± 0.2 °C or ± 0.2 % of Span, Sensor: Class A in accordance to IEC751
  • Approvals CE
  • Diameter 15 mm
  • Electrical Connection M12 4 pin Male
  • Electrical Output 4 to 20 mA
  • EMC In accordance to EN 61326
  • Enclosure Ratings IP65, IP67
  • Factory Setting 0 to 150°C
  • Input Configuration M12TX-CONFIG-SET configuration kit (PC with OS Windows® required)
  • Input Electrical Connection M12 4 pin Female
  • Input Noise 0 to 1.5 Hz: 1.4 µVRMS (RTI)
  • Input Range -50 to 500 °C
  • Isolation Non-isolated
  • Load Resistance 700Ω @ 24Vdc, [RLo= (Vsupply-8,5)/0,020]
  • Materials Thermoplastic
  • Operating Temperature, Max 80 °C
  • Operating Temperature, Min -40 °C
  • Output Signal Current
  • Protection Supply Protection: polarity protected
  • Relative Humidity 0 to 100%
  • Response Time <50 ms
  • Response Time Note <50 ms @ 90%
  • Sensor Break Detection Selectable: Upscale (>21.0 mA) or downscale (<3.6 mA) action;Sensor Short-Circuit: Fixed to downscale (<3.6 mA) action
  • Sensor Error Compensation Note Over 2 points (maximum 1% of span)
  • Sensor Type 100 Ω RTD
  • Span, Min 50°C
  • Span Note 50°C (122°F) [if the zero value is set between one of these values: -40°C (-40°F), -20°C (-4°F), 0°C (32°F), 20°C (68°F), 40°C (104°F), the minimum span is 20°C (68°F) rather than 50°C (122°F)]
  • Supply Power 8.5 to 32 Vdc
  • Supply Power Type DC
  • Temperature Coefficient α = 0.00385/°C
  • Temperature Influence, Max ± 0.3°C/25°C or ± 0.3% of span/25°C
  • Zero Setting Adjustable Range -50 to 50°C

The M12TX temperature transmitter for pt100 RTD is easily ranged and programmable by a computer.The configuration kit required for programming is M12TX-CONFIG. This unique transmitter is ideal for areas with space limitations where traditional head connections are too large to fit.The M12 thread design offers a secure industrial connection. The integrated connection allows the transmitter to be mounted directly on to the sensor.

Accessories

accessories

Configuration kit for M12TX, USB serial interface, connection cables, programming so ftware for Windows®
C$487.23
0 In Stock
This item is discontinued. Please contact Technical Sales Team for assistance.
CONFIGURATION KIT FOR M12TX SENSORS
C$647.74
0 In Stock

sensors

RTD 1/8X6" M12CONN
C$106.21
51 In Stock
PT100 RTD Probes with M12 Molded Connectors
C$115.65
13 In Stock
PT100 RTD Probes with M12 Molded Connectors
C$129.24
14 In Stock
Vibration Resistant and Bendable RTD (Pt100) Probes with M12 Connector and Mounting Threads (Fractional Sizes)
C$301.92
0 In Stock
Bendable and Vibration Resistant RTD Probes with High Temperature Molded M12 Connector
C$192.92
1 In Stock
Rated 1 out of 5 by from Not pleased, will avoid in the future The company is not easy to deal with. The communication is not good.
Date published: 2025-04-15
  • y_2025, m_10, d_17, h_7
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_1
  • loc_en_CA, sid_M12TX-PT100, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 34ms
  • REVIEWS, PRODUCT

How do You program it?

Asked by: Gabby
Hi, thanks for reaching out to us about programming. You will need the M12TX-CONFIG. Also, our Tech Support engineer has reached out and sent you the manuals to assist with programming. Thank you for being an Omega customer.
Answered by: Jane
Date published: 2019-05-31
  • y_2025, m_10, d_17, h_7CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_1
  • loc_en_CA, sid_M12TX-PT100, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 82ms
  • QUESTIONS, PRODUCT
en-CA
en_CA
Save Configuration