Skip to search Skip to main content Skip to navigation

AWS outage: New customer registration is currently unavailable. Order processing may be delayed.

We noticed you are from . Visit your local site for regional offers and live support.

DRSL-DC1-DC2-Srs-Sig-Cond

DIN Rail Conditioner Series with Process Input, High accuracy

Models In Stock
  • Isolation and Conversion of Process Voltage or Current Signals
  • Power Supply and Signal Isolator for 2-Wire Transmitter
  • Slimline Housing—Only 6 mm (0.24') Wide
  • Multiple Signal Ranges (DIP-Switch Selectable)
DRSL-DC1-DC2-Srs-Sig-Cond
From C$ 363.00
Models In Stock
DIN Rail Conditioner Series with Process Input, High accuracy DRSL-DC1-DC2-Srs-Sig-Cond DRSL-DC1-DC2-Srs-Sig-Cond
loading all models
Product Overview
  • Accuracy ± 0.05 %
  • Approvals CE, UL, RoHS
  • Calibration Temperature, Max 28 °C
  • Calibration Temperature, Min 20 °C
  • Conversion Rate 1:1
  • Current Measurement Range 0 to 20.5 mA
  • Electrical Output 0 to 20.5 mA
  • EMC Immunity Note Extended EMC Immunity NAMUR NE 21, A Criterion, Burst: <±1% of span
  • EMC Standard NAMUR NE 21
  • Enclosure Ratings IP20
  • Height 113 mm
  • Installation Pollution degree 2 and measurement/overvoltage category II
  • Length 115 mm
  • Load Resistance Current Output: 23 mA/600 Ω max
  • Mounting DIN Rail 35 mm Standard, EN 60715
  • MTBF 284 yrs
  • Noise Calibration >60 dB
  • Operating Temperature, Max 70 °C
  • Operating Temperature, Min -25 °C
  • Output Value Process
  • Relative Humidity 0 to 95% RH (non-condensing)
  • Response Time < 7 ms
  • Response Time Note Response Time (0 to 90%, 100 to 10%): <7 ms
  • Screw Terminal Torque 0.5 Nm
  • Stability Load Stability: ≤0.01% of span/100 Ω
  • Storage Temperature, Max 85 °C
  • Storage Temperature, Min -40 °C
  • Supply Power Type DC
  • Supply Voltage 16.8 to 31.2 Vdc
  • Temperature Coefficient <±0.01% of span/°C
  • Weight 70 g
  • Width 6.1 mm
  • Wire Gauge 26 to 12 AWG
The DRSL-DC2 isolated DIN rail signal conditioner provides a competitive choice in terms of both price and technology for galvanic isolation of process voltage or current signals to SCADA systems or PLC equipment. The DRSL-DC2 can be used for signal conversion of standard process voltage or current signals. The unit offers isolation between input, output and supply, provides surge suppression and protects control systems from transients and noise.
The DRSL-DC2 also eliminates ground loops and can be used for measuring floating signals. Low power consumption facilitates DIN rail mounting without the need for any air gap. Factory calibrated measurement ranges are easily configured via DIP switches. When the input is configured for 2-wire transmitter mode, the DRSL-DC2 provides the current loop supply voltage. The unit operates over a wide temperature range from -25 to 70°C (-13 to 158°F).

Accessories

installation hardware

Module stop (screwed onto DIN rail to support and hold mounted devices)
C$14.81
35 In Stock
Power rail (with cover and two end covers, one right hand and one le ft hand), 1 m (3.3 ft) length
C$301.98
4 In Stock

meters/controllers

Power connector unit, 24 Vdc/2.5 A output to power rail
C$193.94
14 In Stock
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

Would this work for high speed pulses coming from an encoder?

Asked by: Alff
Thank you for your inquiry. This product will only accept analog dc voltage or current inputs only.
Answered by: Application Engineer JB
Date published: 2023-12-11
  • y_2025, m_10, d_19, h_11CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_1
  • loc_en_CA, sid_DRSL-DC1, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 9ms
  • QUESTIONS, PRODUCT
en-CA
en_CA
Save Configuration