1-800-663-4209 | Vos commentaires sont importants, répondez à un sondage rapide commentaires sur le site web

FPD2000-Series
Débitmètres Volumétriques à Déplacement Positif
High Pressure and Temperature Positive Displacement Flow Meters
Modèles en stock
- ±0,5 % de précision de lecture
- Corps en aluminium ou en acier inoxydable de type 303 ou 316
- Pression nominale jusqu'à 345 bar (5 000 psi)
- Sortie à impulsion ou en mA
- Capacités d'écoulement bidirectionnel
- Prix économique
FPD2000-Series
Depuis
C$
2 420.00
Modèles en stock

L'aperçu du produit
- Accuracy ± 0.5 %
- Accuracy Detail ±0.5% over 10:1 turndown with 30cP fluid
- Amplitude Note 1 to 40 Vp-p
- Display No Display
- Driving Method 50 mA max resistive load
- Duty Cycle 50 % ± 15 %
- Impedance Output Note 40 Ω - analog switch and self-resetting fuse
- Linearity ±0.01% rdg
- Media Compatibility Hydraulic Oil, Light Oil, Oil
- Operating Pressure, Max 5000 psi
- Operating Temperature, Max 85 °C
- Operating Temperature, Min -40 °C
- Process Connection Type NPT Female
- Process Temperature, Min 0 °C
- Repeatability ±0.1%
- Supply Power Note 8 mA @ 12 Vdc,12 mA @ 24 Vdc
- Supply Power Type DC
The FPD2000 Series represents a positive displacement meter that is affordable and accurate. One primary feature is the ability to maintain consistent accuracy despite changing viscosity conditions. This reliability, coupled with a large turndown range, offers an affordable replacement for older turbine technology. The meter’s solid construction and excellent dynamic response are well suited to the measurement of oil, grease, fuel, solvents, polyurethanes, brake fluid, skydrol as well as other nonabrasive lubricating fluids. Since there is no need for straight run piping upstream or downstream of the flow meter, the FPD2000 flow meters are simple to use and to install. The meters produce good resolution and high accuracy at low flow rates. Flow may be bidirectional, such as for cylinder position measurements, without damage to internal parts.
SPECIFICATIONS
Accuracy: ± 0.5% over 10:1 turndown with 30cP fluid
Repeatability: ± 0.1%
Max Fluid Temperature:
Aluminum Body: Meter 85°C (185°F)
Stainless Body: Meter 204°C (400°F)
Pressure Maximum: 345 bar (5000 psi)
Wetted Materials
Body:
FPD2000 Series: Aluminum
FPD2010 Series: 303 stainless steel
FPD2020 Series: 316 stainless steel
Gear: Stainless steel
O-Ring: PTFE, FKM (optional)
Bearings: Stainless steel
Outputs
Temperature Range (Electronics):
Standard Aluminum and Stainless Steel versions: -40 to 85°C (-40 to 185°F)
Square Wave: (Basic unit)
Supply Voltage: +10 to 28 Vdc
Supply Current: 8 mA @ 12 Vdc, 12 mA @ 24 Vdc
Duty Signal: 50% ± 15%
Minimum Signal: 0.5 Hz
Frequency: Flow dependent, up to 2000 Hz
Driving Capacity: 50 mA max resistive load
Output Impedance: 40? - analog switch and self-resetting fuse
Analog Output (-A Models)
Supply Voltage: 10 to 30 Vdc
Output: 4 to 20 mA
Input: 0.25 Hz to 5 KHz
Amplitude: 1 Vp-p to 40 Vp-p
Update Time: 1/F + 25 msec
Linearity: ± 0.01% of reading
Enclosure Rating: IP54
SPECIFICATIONS
Accuracy: ± 0.5% over 10:1 turndown with 30cP fluid
Repeatability: ± 0.1%
Max Fluid Temperature:
Aluminum Body: Meter 85°C (185°F)
Stainless Body: Meter 204°C (400°F)
Pressure Maximum: 345 bar (5000 psi)
Wetted Materials
Body:
FPD2000 Series: Aluminum
FPD2010 Series: 303 stainless steel
FPD2020 Series: 316 stainless steel
Gear: Stainless steel
O-Ring: PTFE, FKM (optional)
Bearings: Stainless steel
Outputs
Temperature Range (Electronics):
Standard Aluminum and Stainless Steel versions: -40 to 85°C (-40 to 185°F)
Square Wave: (Basic unit)
Supply Voltage: +10 to 28 Vdc
Supply Current: 8 mA @ 12 Vdc, 12 mA @ 24 Vdc
Duty Signal: 50% ± 15%
Minimum Signal: 0.5 Hz
Frequency: Flow dependent, up to 2000 Hz
Driving Capacity: 50 mA max resistive load
Output Impedance: 40? - analog switch and self-resetting fuse
Analog Output (-A Models)
Supply Voltage: 10 to 30 Vdc
Output: 4 to 20 mA
Input: 0.25 Hz to 5 KHz
Amplitude: 1 Vp-p to 40 Vp-p
Update Time: 1/F + 25 msec
Linearity: ± 0.01% of reading
Enclosure Rating: IP54
Model No. | Pulses/Liter (Pulses/Gallon) | Body Dia cm (inch) | *Body Heightcm cm (inch) | Filtration (microns) |
---|---|---|---|---|
FPD20X1 | 14,000 (53,000) | 7.6 (3) | 8.6 (3.4) | 30 |
FPD20X2 | 4200 (15,900) | 8.4 (3.3) | 8.6 (3.4) | 30 |
FPD20X3 | 1700 (6600) | 8.4 (3.3) | 8.6 (3.4) | 30 |
FPD20X4 | 470 (1800) | 12.4 (4.9) | 13.8 (5.45) | 30 |
FPD20X5 | 420 (1600) | 21.3 (8.4) | 17 (6.7) | 200 |
PDF et manuels
Accessories
3-pin connector for the FPD2000-A Series
$82.16
0 In Stock
Afficher les notes et les avis
What is the amplitude of the square wave output for model FPD2004?
Thank you for your inquiry about this flow meter. The output wave is equal to the input voltage supplied.
Date published: 2020-10-07
Hello, For the FPD2022 which Digital rate meter do you recommend?
Thank you for your inquiry about the flow meter. The DPF78 is a compatible meter to display the flow rate and accept the frequency output from the sensor.
Date published: 2023-03-27