Need assistance? Call us: 1-800-663-4209
Q8-B8-Series
BACnet MSTP, Expl Proof, Smart Sensor, 0-250 ppm, 3 SPDT Relays, NEMA 4X
- Mechanical Rooms
- Warehouses
- Refrigeration Plants
- Industrial Plants
- Process Monitoring
- Leak Detection
- Parking Garages
- Auto/Truck Maintenance Facilities
- Oil and Gas Industry
Q8-B8-Series
From
$
182.00
Product Overview
- Applications Access and Parking Control Systems, Building and Maintenance, Industrial and Manufacturing, Power Plants & Boilers, Refrigeration Equipment
- Approvals RoHS, CSA-Class 4828-02 inspected to C22.2 No. 30 and No. 142 (CSA File #: 088890_0_000)
- Baud Rate Note Q8 Communication Baud Rates: 1200, 2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600, 76800 Bits/Second (Default: 4800)
- Cable Type Insulated Shielded
- Calibration Note Factory Calibration Range: See Gas Sensor Selection & Specification Table on back of data sheet; Recommended Maintenance: Catalytic (Combustible): Accuracy & Bump test every 3 months or as required by Code Electrochemical (Toxic): Accuracy & Bump test every 6 months or as required by Code Oxygen/Hydrogen (Toxic): Calibrate every 3 months Infrared: Accuracy and Bump Test yearly
- Compatible Sensors Note Replacement Sensor Modules: See additional on-line Product Literature or Contact ACI
- Conduit Connection 2x 3/4 in NPT Female
- Electrical Connection Screw Terminal
- Enclosure Material Cast Aluminum Expoy
- Enclosure Material Note Industrial Connection Head; Cast Aluminum Epoxy Coated NEMA 4X (IP66), Division 1 Division 2, ANSI/ISA 12.22.01 Class I, Zone 1, AEx d II C, IP66 Zone 1 CSA E60079-1 Ex d II C, Class I, Zone I, IP 66 CSA C22.2 No. 30 Class I, Groups A, B, C, D; Class II Groups E, F, G; Class III
- Enclosure Ratings IP66, NEMA Type 4X
- Fuse Rating 0.75 A Polyswitch
- Height 7.48 in
- Keypad 3 (Non-Intrusive) Magnetic Switches
- LED Indicators Two Green LED’s (Tx/Rx Communication Status), Three Red LED’s (Relays 1, 2 & 3 Status)
- Length 5.12 in
- Load Resistance 4-20 mA Output: 600 Ohms maximum
- Operating Environment Indoor use only
- Operating Humidity 5 to 95% RH, non-condensing
- Operating Temperature, Max 122 °F
- Operating Temperature, Min 32 °F
- Power Consumption 8.4 VA
- Series ID Q8-B8-Series
- Service Life Electrochemical (Toxic): 2 to 3 Years, typical Oxygen/Hydrogen (Toxic): 18 months, typical Catalytic (Combustible): 3 to 5 years, typical Infrared: > 5 years
- Shelf Life 6 months
- Storage Temperature, Max 68 °F
- Storage Temperature, Min 32 °F
- Supply Current 0.3 A
- Tightening Torque 0.37 ft-lb (0.502 Nm) Nominal
- Warm Up Time 24 Hours (Allow 24 hours before calibrating sensor after initial installation)
- Weight 4.35 lb
- Width 5.71 in
- Wire Gauge 24 to 16 AWG
PDFs & Manuals
Accessories
Show Ratings & Reviews