  • Mechanical Rooms
  • Warehouses
  • Refrigeration Plants
  • Industrial Plants
  • Process Monitoring
  • Leak Detection
  • Parking Garages
  • Auto/Truck Maintenance Facilities
  • Oil and Gas Industry
Q8-B8-Series
From $ 182.00
BACnet MSTP, Expl Proof, Smart Sensor, 0-250 ppm, 3 SPDT Relays, NEMA 4X Q8-B8-Series Q8-B8-Series
loading all models
Product Overview
  • Applications Access and Parking Control Systems, Building and Maintenance, Industrial and Manufacturing, Power Plants & Boilers, Refrigeration Equipment
  • Approvals RoHS, CSA-Class 4828-02 inspected to C22.2 No. 30 and No. 142 (CSA File #: 088890_0_000)
  • Baud Rate Note Q8 Communication Baud Rates: 1200, 2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600, 76800 Bits/Second (Default: 4800)
  • Cable Type Insulated Shielded
  • Calibration Note Factory Calibration Range: See Gas Sensor Selection & Specification Table on back of data sheet; Recommended Maintenance: Catalytic (Combustible): Accuracy & Bump test every 3 months or as required by Code Electrochemical (Toxic): Accuracy & Bump test every 6 months or as required by Code Oxygen/Hydrogen (Toxic): Calibrate every 3 months Infrared: Accuracy and Bump Test yearly
  • Compatible Sensors Note Replacement Sensor Modules: See additional on-line Product Literature or Contact ACI
  • Conduit Connection 2x 3/4 in NPT Female
  • Electrical Connection Screw Terminal
  • Enclosure Material Cast Aluminum Expoy
  • Enclosure Material Note Industrial Connection Head; Cast Aluminum Epoxy Coated NEMA 4X (IP66), Division 1 Division 2, ANSI/ISA 12.22.01 Class I, Zone 1, AEx d II C, IP66 Zone 1 CSA E60079-1 Ex d II C, Class I, Zone I, IP 66 CSA C22.2 No. 30 Class I, Groups A, B, C, D; Class II Groups E, F, G; Class III
  • Enclosure Ratings IP66, NEMA Type 4X
  • Fuse Rating 0.75 A Polyswitch
  • Height 7.48 in
  • Keypad 3 (Non-Intrusive) Magnetic Switches
  • LED Indicators Two Green LED’s (Tx/Rx Communication Status), Three Red LED’s (Relays 1, 2 & 3 Status)
  • Length 5.12 in
  • Load Resistance 4-20 mA Output: 600 Ohms maximum
  • Operating Environment Indoor use only
  • Operating Humidity 5 to 95% RH, non-condensing
  • Operating Temperature, Max 122 °F
  • Operating Temperature, Min 32 °F
  • Power Consumption 8.4 VA
  • Series ID Q8-B8-Series
  • Service Life Electrochemical (Toxic): 2 to 3 Years, typical Oxygen/Hydrogen (Toxic): 18 months, typical Catalytic (Combustible): 3 to 5 years, typical Infrared: > 5 years
  • Shelf Life 6 months
  • Storage Temperature, Max 68 °F
  • Storage Temperature, Min 32 °F
  • Supply Current 0.3 A
  • Tightening Torque 0.37 ft-lb (0.502 Nm) Nominal
  • Warm Up Time 24 Hours (Allow 24 hours before calibrating sensor after initial installation)
  • Weight 4.35 lb
  • Width 5.71 in
  • Wire Gauge 24 to 16 AWG

Accessories

Horn and Strobe (Blue)
$876.00 / each
0 In Stock
HORN AND STROBE (GREEN)
$819.00 / each
0 In Stock
WALL MOUNT BASE FOR FSIGSLM500 SERIES (G
$92.00 / each
0 In Stock
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 5ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 3ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
en-US
en
Save Configuration